MétaCan
Menu
Back to cohort
Record W2155726554 · doi:10.1109/tbme.2008.923148

Microfluidic Device for Dielectrophoresis Manipulation and Electrodisruption of Respiratory Pathogen <i> Bordetella pertussis</i>

2008· article· en· W2155726554 on OpenAlexaff
C. de la Rosa, Peter Tilley, Julie D. Fox, K.V.I.S. Kaler

Bibliographic record

VenueIEEE Transactions on Biomedical Engineering · 2008
Typearticle
Languageen
FieldEngineering
TopicMicrofluidic and Bio-sensing Technologies
Canadian institutionsProvincial Laboratory of Public HealthUniversity of Calgary
Fundersnot available
KeywordsDielectrophoresisBordetella pertussisPertussis toxinMicrofluidicsBiologyMaterials scienceNanotechnologyBiochemistrySignal transductionBacteriaGeneticsG protein

Abstract

fetched live from OpenAlex

A miniaturized microfluidic device was developed to facilitate electromanipulation of bacterial respiratory pathogens. The device comprises a microchip with circular aluminum electrodes patterned on glass, which is housed in a microfluidic system fabricated utilizing polydimethylsiloxane. The device provides sample preparation capability by exploiting positive dielectrophoresis (DEP) in conjunction with pulsed voltage for manipulation and disruption of Bordetella pertussis bacterial cells. Positive DEP capture of B. pertussis was successfully demonstrated utilizing 10 Vrms and 1 MHz ac fields. Application of dc pulses (300 V amplitude and 50 micros pulsewidth applied 1 s apart) across the aluminum electrodes resulted in electrodisruption and lysis of B. pertussis bacterial cells. Real-time polymerase chain reaction, a 2(3) factorial experimental design and transmission electron microscopy were used to evaluate bacterial cell manipulation and factors affecting bacterial cell disruption. The main factors affecting bacterial cell disruption were electric field strength, the electrical conductivity of the cell suspension sample, and the combined effect of number of pulses and sample conductivity. The bacterial deoxyribonucleic acid target remained undamaged as a result of DEP and cell lysis experimentation. Our findings suggest that a simple miniaturized microfluidic device can achieve important steps in sample preparation on-chip involving respiratory bacterial pathogens.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.001
Threshold uncertainty score0.003

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0010.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.017
GPT teacher head0.212
Teacher spread0.195 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations43
Published2008
Admission routes1
Has abstractyes

Explore more

Same venueIEEE Transactions on Biomedical EngineeringSame topicMicrofluidic and Bio-sensing TechnologiesFrench-language works237,207