MétaCan
Menu
Back to cohort

Canadian Trial of Physiological Pacing

2004· article· en· W2157843325 on OpenAlex
Charles R. Kerr, Stuart J. Connolly, Hoshiar Abdollah, Robin S. Roberts, Michael Gent, Salim Yusuf, Anne M. Gillis, Anthony Tang, Mario Talajic, George J. Klein, David Newman

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

affAt least one author lists a Canadian institution in the pinned OpenAlex snapshot.
fundA Canadian funder is recorded on the work.
aboutThe title or abstract carries a Canadian signal from the geographic lexicon.

Bibliographic record

VenueCirculation · 2004
Typearticle
Languageen
FieldMedicine
TopicCardiac pacing and defibrillation studies
Canadian institutionsMontreal Heart InstituteUniversity of TorontoUniversity of CalgaryUniversity of OttawaUniversity of British ColumbiaWestern University
FundersMedical Research CouncilMedical Research Council Canada
KeywordsMedicineStroke (engine)Atrial fibrillationBradycardiaCardiologyInternal medicineRandomized controlled trialFibrillationCause of deathHeart rateBlood pressureDisease

Abstract

fetched live from OpenAlex

BACKGROUND: The Canadian Trial of Physiological Pacing (CTOPP) reported that the risk of stroke or cardiovascular death was similar between patients receiving ventricular versus physiological pacemakers at the end of the original follow-up period of 3 years. However, the occurrence of atrial fibrillation was significantly less frequent with physiological pacemakers. To assess a potential delayed benefit of physiological pacing, follow-up of patients in this study was extended to 6 years. METHODS AND RESULTS: A total of 1474 patients requiring a pacemaker for symptomatic bradycardia were randomized to receive ventricular and 1094 to physiological pacemakers. The primary outcome was stroke or cardiovascular death. The study was completed in July 1998, and follow-up was extended to July 2001. At a mean follow-up of 6.4 years, there was no difference between treatment groups in the primary outcome of cardiovascular death or stroke. There was no significant difference in total mortality or stroke between groups. There was a significantly lower rate of development of atrial fibrillation in the physiological group, with a relative risk reduction of 20.1% (CI, 5.4 to 32.5; P=0.009). CONCLUSIONS: The CTOPP extended study does not show a difference in cardiovascular death or stroke, or in total mortality, or in stroke between patients implanted with ventricular or physiological pacemakers over a mean follow-up of >6 years. However, there is a persistent significant reduction in the development of atrial fibrillation with physiological pacing.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.356
Threshold uncertainty score0.832

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.044
GPT teacher head0.300
Teacher spread0.256 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it