Design and construction of a prototype high‐power <i>B</i><sub>0</sub> insert coil for field‐cycled imaging in superconducting MRI systems
Bibliographic record
Abstract
Abstract Field‐cycled MRI provides a noninvasive quantification of the concentration of bound (activated) targeted contrast agents. For field‐cycled imaging to be performed within a clinical full‐body superconducting MRI magnet, an auxiliary insertable magnet is required that can dynamically change the main field strength during the MR pulse sequence. Herein, the design and construction of a solenoidal insert coil is discussed. Design aspects including active shielding, thermal performance, forces, and ramping times are examined. Proper materials, construction methods, and interfacing for the insert coil with a clinical MRI are also covered. Finally, a field‐cycled experiment in a 1.5 T clinical MRI system is described, demonstrating the feasibility of this method and then future novel contrasts available with field‐cycled MRI. © 2009 Wiley Periodicals, Inc. Concepts Magn Reson Part B (Magn Reson Engineering) 35B: 1–10, 2009
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.000 | 0.000 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.000 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one teacher head, not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".