MétaCan
Menu
Back to cohort
Record W2159436884 · doi:10.1504/ijbbr.2011.043748

Robot assisted rehabilitation for elbow and forearm movements

2011· article· en· W2159436884 on OpenAlexaff
Mohammad Habibur Rahman, Thierry Kittel Ouimet, Maarouf Saad, Jean‐Pierre Kenné, Philippe S. Archambault

Bibliographic record

VenueInternational Journal of Biomechatronics and Biomedical Robotics · 2011
Typearticle
Languageen
FieldMedicine
TopicStroke Rehabilitation and Recovery
Canadian institutionsÉcole de Technologie Supérieure
Fundersnot available
KeywordsForearmKinematicsExoskeletonElbowController (irrigation)Powered exoskeletonPhysical medicine and rehabilitationJoystickSimulationWristEngineeringRobotRehabilitationComputer scienceArtificial intelligencePhysical therapyMedicine

Abstract

fetched live from OpenAlex

The movements of the shoulder, elbow, and wrist play a vital role in the performance of essential daily activities. We therefore have developed a 2DOF exoskeleton robot ( ExoRob ) to rehabilitate the elbow and forearm movements of physically disabled individuals with impaired upper-limb function. The proposed ExoRob is supposed to be worn on the lateral side of forearm in order to provide naturalistic range movements of elbow (flexion/extension) and forearm (pronation/supination) motions. This paper focuses on the modelling, design (electrical and mechanical components), development, and control of the proposed ExoRob . The kinematic model of ExoRob has been developed based on modified Denavit-Hartenberg notations. Non-linear modified computed torque control technique is employed to control the proposed ExoRob , where trajectories (i.e., pre-programmed trajectories recommended by therapist/clinician) tracking corresponding to typical rehabilitation (passive) exercises has been carried out to evaluate the performances of the developed ExoRob and controller. Furthermore, experiments were carried out with the master exoskeleton arm [ mExoArm , an upper-limb prototype 7DOF (lower scaled) exoskeleton arm] where subjects (robot users) or experimenter operate the mExoArm (like a joystick) to manoeuvre the proposed ExoRob to provide passive rehabilitation. Experimental results show that the controller is able to manoeuvre the ExoRob efficiently to track the desired trajectories. Such movements are widely used in rehabilitation and have been performed efficiently with the developed ExoRob and the controller.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.826
Threshold uncertainty score0.315

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.027
GPT teacher head0.301
Teacher spread0.275 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations15
Published2011
Admission routes1
Has abstractyes

Explore more

Same venueInternational Journal of Biomechatronics and Biomedical RoboticsSame topicStroke Rehabilitation and RecoveryFrench-language works237,207