MétaCan
Menu
Back to cohort

Effect of Diameter and Length on Stress Distribution of the Alveolar Crest around Immediate Loading Implants

2008· article· en· W2160434475 on OpenAlexvenueno aff
Xi Ding, Shenghui Liao, Xinghao Zhu, Xiuhua Zhang, Lin Zhang

Bibliographic record

VenueClinical Implant Dentistry and Related Research · 2008
Typearticle
Languageen
FieldDentistry
TopicDental Implant Techniques and Outcomes
Canadian institutionsnot available
Fundersnot available
KeywordsMaterials scienceImplantBiomechanicsFinite element methodDental implantCrestStress (linguistics)Oblique caseMandible (arthropod mouthpart)Dental alveolusAlveolar crestBiomedical engineeringDentistryOrthodonticsStructural engineeringMedicineSurgeryAnatomyEngineering

Abstract

fetched live from OpenAlex

BACKGROUND: Many clinical observations have shown that immediate loading is indicated when the stabilization of the bone/implant is optimal and when the estimated loads are not excessively high. Nonetheless, more experimental studies are needed to consider the immediate loading protocol as a safe procedure. Mechanical analysis using the finite element (FE) method analysis has been employed by many authors to understand the biomechanical behavior around dental implants. PURPOSE: This study was to evaluate the effect of the diameter and length on the stress and strain distribution of the crestal bone around implants under immediate loading. MATERIALS AND METHODS: By an ad hoc automatic mesh generator, high-quality FE models of complete range mandible was constructed from computer tomography, with three Straumann (Straumann Institute, Waldenburg, Switzerland) implants of various sizes embedded in the anterior zone. The implant diameter ranged from 3.3 to 4.8 mm, and length ranged from 6 to 14 mm, resulting in seven designs. The implant-bone interface was simulated by nonlinear frictional contact algorithm. For each design, vertical and oblique loadings of 150 N were applied, respectively, to each implant, and stresses and strains in the surrounding cortical bone were evaluated. RESULTS: The biomechanics analysis provided results that the oblique loading would induce significantly higher interfacial stresses and strains than the vertical loading, while the intergroup stress difference significant levels was evaluated using t-tests method and the level of significance (.05) that was accepted for significance. Under both loadings, the maximal values were recorded in the 3.3 (diameter) x 10 (length) mm implant configuration, whose mean and peak values were both higher than that of others with significant statistical differences. The second maximal one is 4.1 x 6 mm configuration, and the minimal stresses were recorded in 4.8 x 10 mm configuration, whose strains were also near to lowest. CONCLUSIONS: Increasing the diameter and length of the implant decreased the stress and strain on the alveolar crest, and the stress and strain values notably increased under buccolingual loading as compared with vertical loading, but diameter had a more significant effect than length to relieve the crestal stress and strain concentration.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.002
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.004

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.002
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.086
GPT teacher head0.438
Teacher spread0.352 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations121
Published2008
Admission routes1
Has abstractyes

Explore more

Same venueClinical Implant Dentistry and Related ResearchSame topicDental Implant Techniques and OutcomesFrench-language works237,207