MétaCan
Menu
Back to cohort
Record W2161559055 · doi:10.1088/0967-3334/36/5/983

Preprocessing and parameterizing bioimpedance spectroscopy measurements by singular value decomposition

2015· article· en· W2161559055 on OpenAlexafffund
Isar Nejadgholi, Herschel Caytak, Miodrag Bolić, Izmail Batkin, Shervin Shirmohammadi

Bibliographic record

VenuePhysiological Measurement · 2015
Typearticle
Languageen
FieldMedicine
TopicBody Composition Measurement Techniques
Canadian institutionsUniversity of Ottawa
FundersNatural Sciences and Engineering Research Council of CanadaMitacs
KeywordsParameterized complexitySingular value decompositionStandard deviationPreprocessorMathematicsStatisticsAlgorithmComputer scienceArtificial intelligence

Abstract

fetched live from OpenAlex

In several applications of bioimpedance spectroscopy, the measured spectrum is parameterized by being fitted into the Cole equation. However, the extracted Cole parameters seem to be inconsistent from one measurement session to another, which leads to a high standard deviation of extracted parameters. This inconsistency is modeled with a source of random variations added to the voltage measurement carried out in the time domain. These random variations may originate from biological variations that are irrelevant to the evidence that we are investigating. Yet, they affect the voltage measured by using a bioimpedance device based on which magnitude and phase of impedance are calculated.By means of simulated data, we showed that Cole parameters are highly affected by this type of variation. We further showed that singular value decomposition (SVD) is an effective tool for parameterizing bioimpedance measurements, which results in more consistent parameters than Cole parameters. We propose to apply SVD as a preprocessing method to reconstruct denoised bioimpedance measurements. In order to evaluate the method, we calculated the relative difference between parameters extracted from noisy and clean simulated bioimpedance spectra. Both mean and standard deviation of this relative difference are shown to effectively decrease when Cole parameters are extracted from preprocessed data in comparison to being extracted from raw measurements.We evaluated the performance of the proposed method in distinguishing three arm positions, for a set of experiments including eight subjects. It is shown that Cole parameters of different positions are not distinguishable when extracted from raw measurements. However, one arm position can be distinguished based on SVD scores. Moreover, all three positions are shown to be distinguished by two parameters, R0/R∞ and Fc, when Cole parameters are extracted from preprocessed measurements. These results suggest that SVD could be considered as an effective technique for overcoming the variability of bio-impedance spectroscopy measurements.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.003
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: none
GenreCandidate signal: Methods · Consensus signal: Methods
Teacher disagreement score0.001
Threshold uncertainty score0.005

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.003
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0010.001
Science and technology studies0.0000.001
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0010.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.175
GPT teacher head0.361
Teacher spread0.186 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreMethods

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations10
Published2015
Admission routes2
Has abstractyes

Explore more

Same venuePhysiological MeasurementSame topicBody Composition Measurement TechniquesFrench-language works237,207