MétaCan
Menu
Back to cohort
Record W2163503047 · doi:10.1503/cmaj.141349

Prospective validation of a 1-hour algorithm to rule-out and rule-in acute myocardial infarction using a high-sensitivity cardiac troponin T assay

2015· article· en· W2163503047 on OpenAlex

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

venuePublished in a venue whose home country is Canada.
no affNo Canadian affiliation: this work is invisible to an affiliation-only frame.
No Canadian affiliation. An affiliation-only frame, the usual design, would never have seen this work. It is one of the works that make the case for inverting the frame.

Bibliographic record

VenueCanadian Medical Association Journal · 2015
Typearticle
Languageen
FieldMedicine
TopicAcute Myocardial Infarction Research
Canadian institutionsnot available
FundersAlereSchweizerische HerzstiftungUniversitätsspital BaselAstraZenecaSchweizerischer Nationalfonds zur Förderung der Wissenschaftlichen ForschungNational Science Foundation
KeywordsMedicineMyocardial infarctionAlgorithmInternal medicineCardiologyTroponinClinical prediction ruleConfidence intervalEmergency departmentAcute coronary syndromePredictive value of testsProspective cohort studyPositive predicative valueMyocardial infarction diagnosisPredictive valueMathematics

Abstract

fetched live from OpenAlex

BACKGROUND: We aimed to prospectively validate a novel 1-hour algorithm using high-sensitivity cardiac troponin T measurement for early rule-out and rule-in of acute myocardial infarction (MI). METHODS: In a multicentre study, we enrolled 1320 patients presenting to the emergency department with suspected acute MI. The high-sensitivity cardiac troponin T 1-hour algorithm, incorporating baseline values as well as absolute changes within the first hour, was validated against the final diagnosis. The final diagnosis was then adjudicated by 2 independent cardiologists using all available information, including coronary angiography, echocardiography, follow-up data and serial measurements of high-sensitivity cardiac troponin T levels. RESULTS: Acute MI was the final diagnosis in 17.3% of patients. With application of the high-sensitivity cardiac troponin T 1-hour algorithm, 786 (59.5%) patients were classified as "rule-out," 216 (16.4%) were classified as "rule-in" and 318 (24.1%) were classified to the "observational zone." The sensitivity and the negative predictive value for acute MI in the rule-out zone were 99.6% (95% confidence interval [CI] 97.6%-99.9%) and 99.9% (95% CI 99.3%-100%), respectively. The specificity and the positive predictive value for acute MI in the rule-in zone were 95.7% (95% CI 94.3%-96.8%) and 78.2% (95% CI 72.1%-83.6%), respectively. The 1-hour algorithm provided higher negative and positive predictive values than the standard interpretation of highsensitivity cardiac troponin T using a single cut-off level (both p < 0.05). Cumulative 30-day mortality was 0.0%, 1.6% and 1.9% in patients classified in the rule-out, observational and rule-in groups, respectively (p = 0.001). INTERPRETATION: This rapid strategy incorporating high-sensitivity cardiac troponin T baseline values and absolute changes within the first hour substantially accelerated the management of suspected acute MI by allowing safe rule-out as well as accurate rule-in of acute MI in 3 out of 4 patients. TRIAL REGISTRATION: ClinicalTrials.gov, NCT00470587.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.006
metaresearch head score (Gemma)0.004
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.085
Threshold uncertainty score0.999

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0060.004
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0010.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.017
GPT teacher head0.299
Teacher spread0.283 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it