MétaCan
Menu
Back to cohort
Record W2164091078 · doi:10.1109/tmi.2009.2024684

Rapid Dynamic Image Registration of the Beating Heart for Diagnosis and Surgical Navigation

2009· article· en· W2164091078 on OpenAlexafffund
Xishi Huang, Jing Ren, G Guiraudon, Derek R. Boughner, Terry M. Peters

Bibliographic record

VenueIEEE Transactions on Medical Imaging · 2009
Typearticle
Languageen
FieldMedicine
TopicAdvanced MRI Techniques and Applications
Canadian institutionsWestern UniversityLondon Health Sciences CentreOntario Tech UniversityRobarts Clinical TrialsHospital for Sick Children
FundersCanadian Institutes of Health ResearchHealth Research Board
KeywordsImaging phantomImage registrationMetric (unit)Image qualityContext (archaeology)Artificial intelligenceCardiac imagingComputer visionComputer scienceMagnetic resonance imagingMedicineRadiologyImage (mathematics)

Abstract

fetched live from OpenAlex

Dynamic cardiac magnetic resonance imaging (MR) and computed tomography (CT) provide cardiologists and cardiac surgeons with high-quality 4-D images for diagnosis and therapy, yet the effective use of these high-quality anatomical models remains a challenge. Ultrasound (US) is a flexible imaging tool, but the US images produced are often difficult to interpret unless they are placed within their proper 3-D anatomical context. The ability to correlate real-time 3-D US volumes (RT3D US) with dynamic MR/CT images would offer a significant contribution to improve the quality of cardiac procedures. In this paper, we present a rapid two-step method for registering RT3D US to high-quality dynamic 3-D MR/CT images of the beating heart. This technique overcomes some major limitations of image registration (such as the correct registration result not necessarily occurring at the maximum of the mutual information (MI) metric) using the MI metric. We demonstrate the effectiveness of our method in a dynamic heart phantom (DHP) study and a human subject study. The achieved mean target registration error of CT+US images in the phantom study is 2.59 mm. Validation using human MR/US volumes shows a target registration error of 1.76 mm. We anticipate that this technique will substantially improve the quality of cardiac diagnosis and therapies.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.005
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.003
Threshold uncertainty score0.011

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.005
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0010.001
Science and technology studies0.0000.000
Scholarly communication0.0010.001
Open science0.0010.002
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0030.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.013
GPT teacher head0.336
Teacher spread0.323 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations47
Published2009
Admission routes2
Has abstractyes

Explore more

Same venueIEEE Transactions on Medical ImagingSame topicAdvanced MRI Techniques and ApplicationsFrench-language works237,207