MétaCan
Menu
Back to cohort
Record W2165566949 · doi:10.1109/ipemc.2009.5157823

Decoupled power control for an inverter based low voltage microgrid in autonomous operation

2009· article· en· W2165566949 on OpenAlex

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

affAt least one author lists a Canadian institution in the pinned OpenAlex snapshot.
fundA Canadian funder is recorded on the work.

Bibliographic record

Venuenot available
Typearticle
Languageen
FieldEngineering
TopicMicrogrid Control and Optimization
Canadian institutionsUniversity of Alberta
FundersNatural Sciences and Engineering Research Council of Canada
KeywordsMicrogridVoltage droopAC powerIslandingDistributed generationComputer scienceControl theory (sociology)Automatic frequency controlElectric power systemReactanceInverterPower controlPower (physics)EngineeringVoltageRenewable energyElectrical engineeringControl (management)Voltage source

Abstract

fetched live from OpenAlex

With the increasing concerns for the traditional energy shortage and environment issues, distributed generation (DG) systems based on renewable energy sources (RES) have experienced a fast development in recent years. With more DG units being integrated into the power system, a more recent concept, called microgrid, is developed by grouping a cluster of loads and parallel DG units in a local area. This paper addresses the issue of real and reactive power control for DG units in a low voltage (LV) microgrid during the autonomous islanding operation. The traditional method for power control in parallel DG systems is the frequency and voltage magnitude droop method, which is based on the assumption of a mainly inductive line impedance, and is subject to power control couplings when implemented in a LV microgrid, where the line resistance to reactance ratio (R/X) is high. It is also revealed in this paper that the traditional droop control can lead to stability concerns in a LV microgrid. To achieve accurate and decoupled real and reactive power control and at the same time, to improve the system stability, a virtual frequency-voltage frame control is proposed, where the original voltage and frequency frame is transformed to a virtual frame to realize a completely decoupled relationship between real and reactive power. Details of frame transformation control and small signal stability analysis are presented. Both simulation and experimental results are provided in this paper.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: Simulation or modeling
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.910
Threshold uncertainty score0.524

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.004
GPT teacher head0.196
Teacher spread0.192 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Quick stats

Citations80
Published2009
Admission routes2
Has abstractyes

Explore more

Same topicMicrogrid Control and OptimizationFrench-language works237,207