MétaCan
Menu
Back to cohort
Record W2165980998 · doi:10.1016/j.eupc.2005.01.005

Automatic analysis of pacemaker diagnostic data in the identification of atrial tachyarrhythmias in patients with no prior history of them

2005· article· en· W2165980998 on OpenAlexaff
Andreas Schuchert, Serge Lepage, Jack Ostrander, R. van den Bos, Marianne Gwechenberger, Ann Nicholls, G. Ringwald

Bibliographic record

VenueEP Europace · 2005
Typearticle
Languageen
FieldMedicine
TopicCardiac pacing and defibrillation studies
Canadian institutionsSouth Bruce Grey Health CentreCentre Hospitalier Universitaire de Sherbrooke
Fundersnot available
KeywordsMedicineIncidence (geometry)CardiologyInternal medicine

Abstract

fetched live from OpenAlex

AIMS: Modern pacemakers provide a large amount of diagnostic data. Given the limited time available during a pacemaker follow-up visit essential information may be overlooked. This registry was conducted to assess the utility of an expert system that analyses the diagnostic data collected by an implanted pacing device and notifies and advises the physician about suspected technical issues and arrhythmias that need further attention. METHODS: Patients with various standard indications for pacing were included in this registry and received single or dual chamber pacemakers. Data were collected and analysed by the expert system during at least two subsequent follow-up visits. The evaluation of this system focused on data obtained from patients with a dual chamber pacing device without prior history of atrial arrhythmias. RESULTS: A total number of 239 patients without prior history of atrial tachyarrhythmias were included in this analysis. Atrial tachyarrhythmias were detected in 73 (31%) of these patients. The highest incidence of newly detected arrhythmias occurred in the group of patients with high-degree AV block and VDD pacemakers. Furthermore, newly detected arrhythmias predominantly occurred in the period shortly after implantation. Device programming suggestions by the expert system were adopted in 30% of the cases. Following detection of atrial tachyarrhythmias by the expert system, pharmacological management was adjusted at 71% of the first follow-up visits and at 27% of later follow-up visits. CONCLUSION: Results of this registry show that this expert system provides a valuable tool for the detection of atrial tachyarrhythmias during pacemaker follow-up visits.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.002
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.006
Threshold uncertainty score0.231

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.002
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.028
GPT teacher head0.274
Teacher spread0.247 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations18
Published2005
Admission routes1
Has abstractyes

Explore more

Same venueEP EuropaceSame topicCardiac pacing and defibrillation studiesFrench-language works237,207