MétaCan
Menu
Back to cohort
Record W2167527394 · doi:10.1056/nejmoa1014597

Normothermic Ex Vivo Lung Perfusion in Clinical Lung Transplantation

2011· article· en· W2167527394 on OpenAlex

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

affAt least one author lists a Canadian institution in the pinned OpenAlex snapshot.
fundA Canadian funder is recorded on the work.

Bibliographic record

VenueNew England Journal of Medicine · 2011
Typearticle
Languageen
FieldMedicine
TopicTransplantation: Methods and Outcomes
Canadian institutionsSt. Michael's HospitalUniversity of Toronto
FundersAstellas PharmaUniversity of Toronto
KeywordsMedicineTransplantationLung transplantationLungMechanical ventilationFraction of inspired oxygenPerfusionAnesthesiaSurgeryCardiologyInternal medicine

Abstract

fetched live from OpenAlex

BACKGROUND: More than 80% of donor lungs are potentially injured and therefore not considered suitable for transplantation. With the use of normothermic ex vivo lung perfusion (EVLP), the retrieved donor lung can be perfused in an ex vivo circuit, providing an opportunity to reassess its function before transplantation. In this study, we examined the feasibility of transplanting high-risk donor lungs that have undergone EVLP. METHODS: In this prospective, nonrandomized clinical trial, we subjected lungs considered to be high risk for transplantation to 4 hours of EVLP. High-risk donor lungs were defined by specific criteria, including pulmonary edema and a ratio of the partial pressure of arterial oxygen to the fraction of inspired oxygen (PO(2):FIO(2)) less than 300 mm Hg. Lungs with acceptable function were subsequently transplanted. Lungs that were transplanted without EVLP during the same period were used as controls. The primary end point was primary graft dysfunction 72 hours after transplantation. Secondary end points were 30-day mortality, bronchial complications, duration of mechanical ventilation, and length of stay in the intensive care unit and hospital. RESULTS: During the study period, 136 lungs were transplanted. Lungs from 23 donors met the inclusion criteria for EVLP; in 20 of these lungs, physiological function remained stable during EVLP and the median PO(2):FIO(2) ratio increased from 335 mm Hg in the donor lung to 414 and 443 mm Hg at 1 hour and 4 hours of perfusion, respectively (P<0.001). These 20 lungs were transplanted; the other 116 lungs constituted the control group. The incidence of primary graft dysfunction 72 hours after transplantation was 15% in the EVLP group and 30% in the control group (P=0.11). No significant differences were observed for any secondary end points, and no severe adverse events were directly attributable to EVLP. CONCLUSIONS: Transplantation of high-risk donor lungs that were physiologically stable during 4 hours of ex vivo perfusion led to results similar to those obtained with conventionally selected lungs. (Funded by Vitrolife; ClinicalTrials.gov number, NCT01190059.).

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesInsufficient payload (model declined to judge)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.180
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0020.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.057
GPT teacher head0.371
Teacher spread0.314 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it