MétaCan
Menu
Back to cohort
Record W2168814710 · doi:10.2214/ajr.14.12698

Successful Dose Reduction Using Reduced Tube Voltage With Hybrid Iterative Reconstruction in Pediatric Abdominal CT

2015· article· en· W2168814710 on OpenAlexaff
Sheila C. Berlin, Dayna M. Weinert, Pauravi Vasavada, Claudia Martinez‐Rios, Roshni A. Parikh, Michael Wien, David W. Jordan, Ronald D. Novak

Bibliographic record

VenueAmerican Journal of Roentgenology · 2015
Typearticle
Languageen
FieldMedicine
TopicRadiation Dose and Imaging
Canadian institutionsHospital for Sick Children
Fundersnot available
KeywordsMedicineIterative reconstructionNuclear medicineImage qualityConfidence intervalImage noiseRadon transformRadiologyAbdominal computed tomographyRadiation doseImage (mathematics)MathematicsInternal medicineArtificial intelligence

Abstract

fetched live from OpenAlex

OBJECTIVE: The purpose of this article is to assess radiation dose reduction, image quality, and diagnostic confidence using low tube voltage in combination with hybrid iterative reconstruction in contrast-enhanced pediatric abdominal CT. MATERIALS AND METHODS: CT examinations of 133 patients (median age, 10 years) were performed at sequentially reduced doses. The first group (group 1) was scanned using dimension-based protocols at 120 kV for all patient sizes. The optimized group (group 5) was scanned at 80 kV for less than 18 cm in the lateral dimension and 100 kV in the 19-30 cm lateral dimension. CT examinations reconstructed with filtered back projection (FBP) and four levels of hybrid iterative reconstruction were reviewed by four blinded readers for subjective image quality and diagnostic confidence. Objective noise, volume CT dose index (CTDIvol), and size-specific dose estimate (SSDE) were recorded. Data were analyzed using t tests, one and two-way ANOVA, and the intraclass correlation coefficient. RESULTS: Compared with group 1, the radiation dose was reduced for group 5 by 63% measured by SSDE (4.69 vs 10.00 mGy; p < 0.001). Subjective image noise was increased for FBP images (p < 0.001) but not was statistically significantly different for all levels of hybrid iterative reconstruction; artifacts were reduced and visibility of small structures was improved (both p < 0.001). Diagnostic confidence was improved for solid organ injury and metastatic disease (both p < 0.001) and was not statistically significantly different for appendicitis (p = 0.306). CONCLUSION: Use of hybrid iterative reconstruction with low-tube-voltage protocols enables substantial radiation dose reduction for pediatric abdominal CT with equivalent to improved subjective image quality and diagnostic confidence.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.533
Threshold uncertainty score0.461

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.018
GPT teacher head0.282
Teacher spread0.264 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations28
Published2015
Admission routes1
Has abstractyes

Explore more

Same venueAmerican Journal of RoentgenologySame topicRadiation Dose and ImagingFrench-language works237,207