MétaCan
Menu
Back to cohort
Record W2168921403 · doi:10.1016/j.joa.2012.12.003

A short RP narrow QRS rhythm: What is the mechanism?

2013· article· en· W2168921403 on OpenAlexaboutno aff
Michifumi Tokuda, Teiichi Yamane, Seiichiro Matsuo, Mika Hioki, Ryohsuke Narui, Shin‐ichi Tanigawa, Seigo Yamashita, Keiichi Inada, Taro Date, Michihiro Yoshimura

Bibliographic record

VenueJournal of Arrhythmia · 2013
Typearticle
Languageen
FieldMedicine
TopicCardiac Arrhythmias and Treatments
Canadian institutionsnot available
Fundersnot available
KeywordsMedicineQRS complexCardiologyRhythmInternal medicineHeart rateTachycardiaPR intervalElectrocardiographyJunctional rhythmQT intervalAnesthesiaBlood pressure

Abstract

fetched live from OpenAlex

A 75-year-old woman with syncope was hospitalized at our institute. The surface 12-lead electrocardiogram (ECG) at admission indicated a regular short RP rhythm at a rate of 95 beats per minute (bpm) with a narrow QRS complex (Fig. 1A). Echocardiography and enhanced multidetector computed tomography revealed a heart with a normal structure and without significant coronary artery disease. She developed dizziness and nausea while hospitalized. A 12-lead ECG at the time of her symptoms documented a prolongation of the RR interval up to 4 s (Fig. 1B). What is the mechanism of the short-RP narrow QRS rhythm and the prolongation of the RR interval? (A) Surface 12-lead electrocardiogram at admission demonstrated a regular short RP rhythm at a rate of 95 beats per minute with a narrow QRS complex. (B) A continuous electrocardiogram monitoring strip at the emergency room revealed a prolongation of the RR interval. A short RP rhythm without tachycardia (heart rate <100 bpm) is generally recognized as a junctional rhythm with retrograde nodal atrial conduction. In the present case, the ECG during the patient's symptoms (Fig. 1A) indicated an accelerated junctional ectopic rhythm followed by a P wave. However, there was no QRS complex preceding the first P wave at the beginning of the RR prolongation (Fig. 1B). This absence of a QRS complex before the P wave suggests that the atrium is not passively activated by the ectopic beats originating from the atrio-ventricular (AV) node. An AV reciprocating rhythm with a concealed accessory pathway can be excluded. Thus, the mechanism of the short RP rhythm is likely either a sinus rhythm or an ectopic atrial arrhythmia with a long first-degree AV block. The positive P wave morphology in the inferior leads during the short RP rhythm also indicates that the atrium was not activated from the AV node. A positive P wave in lead V1 suggests that the origin of the ectopic rhythm is from the left atrium, with a sensitivity of 93% and a specificity of 88% [1]. In the present case, the morphology of the P wave at admission may have originated not from the sinus node but from the left atrium. On the basis of this mechanism, the prolonged RR interval with the patient's symptoms was likely a reflection of the progression of the AV block with an underlying first-degree AV block. Despite a first-degree AV block (420 ms) during the short RP rhythm, a short PR interval (160 ms) was observed with an advanced AV block (Fig. 1B). Thus, the patient could have a dual AV node pathway. The effective refractory period of the fast pathway can exceed that of the slow pathway. The functional block in the fast pathway can be maintained by repetitive collision of retrograde invasion of impulses conducted through the slow pathway (linking phenomenon) [2]. During an advanced AV block, the antegrade conduction block of the slow pathway can allow the recovery of fast pathway conduction. However, the P wave resulting in the QRS is not the one immediately in front of the QRS but the P wave before that one, conducting with a long PR, which would explain this phenomenon. After temporary pacemaker insertion, adenosine triphosphate (ATP) (100 μg/kg) was rapidly administered to confirm the mechanism of the short RP rhythm (Fig. 2). Following venous administration of adenosine, an advanced AV block was observed with persistent atrial ectopic rhythm similar to that shown in Fig. 1. The prolongation of atrial cycle lengths with ATP injection may suggest that this rhythm has an automaticity mechanism. In conclusion, the present case demonstrated an ectopic rhythm with marked first-degree AV block followed by an advanced AV block resulting in the prolongation of the long RR interval. Twelve-lead electrocardiogram during bolus injection of adenosine triphosphate. An advanced atrio-ventricular block with temporary prolongation of atrial cycle lengths was induced by adenosine triphosphate injection. No conflict of interest disclosed. We are grateful to Stanley Tung, M.D. (St. Paul's Hospital, Vancouver, British Columbia, Canada), for the linguistic comments on the manuscript.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Other design · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.833
Threshold uncertainty score0.916

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.001
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.012
GPT teacher head0.259
Teacher spread0.247 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designOther design
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2013
Admission routes1
Has abstractyes

Explore more

Same venueJournal of ArrhythmiaSame topicCardiac Arrhythmias and TreatmentsFrench-language works237,207