MétaCan
Menu
Back to cohort

3D pulsatile flow in a curved tube with coexisting model of aortic stenosis and coarctation of the aorta

2010· article· en· W2169289022 on OpenAlexaff
Zahra Keshavarz‐Motamed, Lyes Kadem

Bibliographic record

VenueMedical Engineering & Physics · 2010
Typearticle
Languageen
FieldMedicine
TopicCongenital Heart Disease Studies
Canadian institutionsConcordia University
Fundersnot available
KeywordsPulsatile flowAortaCardiologyStenosisMedicineCoarctation of the aortaInternal medicineAortic archHemodynamicsDescending aortaBicuspid aortic valveBlood flowAnatomy

Abstract

fetched live from OpenAlex

Coarctation of the aorta is a congenital heart disease defined as an obstruction of the aorta distal to the left subclavian artery (between the aortic arch and descending aorta). It is usually associated with other diseases such as bicuspid and tricuspid aortic stenosis. If the coarctation remains uncorrected it can lead to hypertension, left ventricular failure and aortic dissection. Numerous investigations pointed out that there is a relationship between the genesis and the progression of cardiovascular disease and the locally irregular flow occurring at the diseased zone. Therefore, to examine the relationship between arterial disease and hemodynamics conditions, detailed quantitative studies on flow dynamics in arterial models are clearly inquired. In this study we numerically investigate pulsatile blood flow in a simplified model of the aorta (curved pipe) with coexisting coarctation of the aorta and aortic stenosis. Three severities of aortic stenoses (0.61 cm(2), 1.0 cm(2) and 1.5 cm(2)) coexisting with aortic coarctations (50%, 75% and 90% by area) are investigated. An experimentally validated numerical model from literature is used and baseline results are validated against it. To ensure having a physiologically relevant model using this geometry, flow properties are set so that the Dean number falls in the physiological range for the aorta. The results show that the coexistence of these pathologies significantly modifies the flow in a curved pipe. The maximal velocity is shifted towards the outer wall and can reach values as high as 5m/s just downstream of the coarctation. The wall shear stress distribution is significantly modified compared to the normal, unobstructed case. Finally, a clinically significant pressure gradient is induced by the curvature of the tube (up to 36 mmHg). This can lead to an overestimation of the severity of the coarctation using catheterization.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: Simulation or modeling
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.011
Threshold uncertainty score0.021

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.001
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0010.000
Science and technology studies0.0010.001
Scholarly communication0.0010.000
Open science0.0010.001
Research integrity0.0020.000
Insufficient payload (model declined to judge)0.0020.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.011
GPT teacher head0.240
Teacher spread0.229 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations41
Published2010
Admission routes1
Has abstractyes

Explore more

Same venueMedical Engineering & PhysicsSame topicCongenital Heart Disease StudiesFrench-language works237,207