MétaCan
Menu
Back to cohort
Record W2170247604 · doi:10.1243/09544119jeim742

The effect of load application rate on the biomechanics of synthetic femurs

2009· article· en· W2170247604 on OpenAlexaff
Radovan Zdero, S Shah, Mohammed H. Mosli, Emil H. Schemitsch

Bibliographic record

VenueProceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · 2009
Typearticle
Languageen
FieldMedicine
TopicOrthopaedic implants and arthroplasty
Canadian institutionsSt. Michael's Hospital
Fundersnot available
KeywordsStiffnessBiomechanicsCadaveric spasmMaterials scienceFemurStructural engineeringComposite materialBiomedical engineeringMathematicsAnatomySurgeryMedicineEngineering

Abstract

fetched live from OpenAlex

Biomechanical investigations are increasingly using commercially available synthetic femurs as surrogates for human cadaveric femurs. However, the rate of force application in testing these artificial femurs appears to be chosen arbitrarily without much consideration to their visco-elastic time-dependent nature. The aim of this study, therefore, was to examine the effect of loading rate on the mechanical behaviour of synthetic femurs. Ten left, medium, fourth-generation composite femurs (Model 3403, Pacific Research Laboratories, Vashon, WA, USA) were fixed distally into cement-filled steel cubic chambers for mounting into a mechanical tester. In randomized order, each of the ten femurs was loaded at rates of 1, 2.5, 5, 7.5, 10, 20, 30, 40, 50, and 60 mm/min to obtain axial, lateral, and torsional stiffness. Axial stiffness showed an aggregate average value of 1742.7 +/- 174.7 N/mm with a high linear correlation with loading rate (R2 = 0.80). Lateral stiffness yielded an aggregate average value of 56.9 +/- 10.2 N/mm and was linearly correlated with loading rate (R2 = 0.85). Torsional stiffness demonstrated an aggregate average value of 176.9 +/- 14.5 N/mm with a strong linear correlation with loading rate (R2 = 0.59). Despite the high correlations between stiffness and speed, practically this resulted in an overall average difference between the lowest and highest stiffness of only 4 per cent. Moreover, no statistical comparisons between loading rates for axial, lateral, or torsional test modes showed differences (p > or = 0.843). Future biomechanical investigators utilizing these synthetic femurs need not be concerned with loading rate effects over the range tested presently. This is the first study in the literature to perform such an assessment.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.003
metaresearch head score (Gemma)0.003
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.088
Threshold uncertainty score0.393

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0030.003
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.008
GPT teacher head0.237
Teacher spread0.228 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations27
Published2009
Admission routes1
Has abstractyes

Explore more

Same venueProceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in MedicineSame topicOrthopaedic implants and arthroplastyFrench-language works237,207