MétaCan
Menu
Back to cohort
Record W2170525007 · doi:10.2460/ajvr.74.5.721

Noninvasive measurements of body composition and body water via quantitative magnetic resonance, deuterium water, and dual-energy x-ray absorptiometry in cats

2013· article· en· W2170525007 on OpenAlexaff
Brian M. Zanghi, Carolyn J. Cupp, Yuanlong Pan, Delphine G. Tissot-Favre, Norton W. Milgram, Tim R. Nagy, Howard Dobson

Bibliographic record

VenueAmerican Journal of Veterinary Research · 2013
Typearticle
Languageen
FieldMedicine
TopicBody Composition Measurement Techniques
Canadian institutionsUniversity of Guelph
Fundersnot available
KeywordsCATSDual-energy X-ray absorptiometryCoefficient of variationNuclear medicineBody waterDilutionLean body massMagnetic resonance imagingChemistryMedicineBody weightRadiologyInternal medicineBone mineralPhysicsChromatography

Abstract

fetched live from OpenAlex

OBJECTIVE: To compare quantitative magnetic resonance (QMR), dual-energy x-ray absorptiometry (DXA), and deuterium oxide (D2O) dilution methods for measurement of total body water (TBW), lean body mass (LBM), and fat mass (FM) in healthy cats and to assess QMR precision and accuracy. ANIMALS: Domestic shorthair cats (58 and 32 cats for trials 1 and 2, respectively). PROCEDURES: QMR scans of awake cats performed with 2 units were followed by administration of D2O tracer (100 mg/kg, PO). Cats then were anesthetized, which was followed by QMR and DXA scans. Jugular blood samples were collected before and 120 minutes after D2O administration. RESULTS: QMR precision was similar between units (coefficient of variation < 2.9% for all measures). Fat mass, LBM, and TBW were similar for awake or sedated cats and differed by 4.0%, 3.4%, and 3.9%, respectively, depending on the unit. The QMR minimally underestimated TBW (1.4%) and LBM (4.4%) but significantly underestimated FM (29%), whereas DXA significantly underestimated LBM (9.2%) and quantitatively underestimated FM (9.3%). A significant relationship with D2O measurement was detected for all QMR (r(2) > 0.84) and DXA (r(2) > 0.84) measurements. CONCLUSIONS AND CLINICAL RELEVANCE: QMR was useful for determining body composition in cats; precision was improved over DXA. Quantitative magnetic resonance can be used to safely and rapidly acquire data without the need for anesthesia, facilitating frequent monitoring of weight changes in geriatric, extremely young, or ill pets. Compared with the D2O dilution method, QMR correction equations provided accurate data over a range of body compositions.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.002
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.003
Threshold uncertainty score0.005

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.002
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.000
Science and technology studies0.0000.001
Scholarly communication0.0000.001
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.081
GPT teacher head0.365
Teacher spread0.284 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations16
Published2013
Admission routes1
Has abstractyes

Explore more

Same venueAmerican Journal of Veterinary ResearchSame topicBody Composition Measurement TechniquesFrench-language works237,207