MétaCan
Menu
← Back to cohort
Record W2171502144 · doi:10.1373/clinchem.2004.032995

Protein Bead Array for the Detection of HIV-1 Antibodies from Fresh Plasma and Dried-Blood-Spot Specimens

2004· article· en· W2171502144 on OpenAlexaffabout
Sylvie Faucher, Alexandre Martel, Alice Sherring, Tao Ding, L Malloch, John E. Kim, M. Bergeron, Paul Sandstrom, Francis Mandy

Bibliographic record

VenueClinical Chemistry · 2004
Typearticle
Languageen
FieldEngineering
TopicBiosensors and Analytical Detection
Canadian institutionsHealth Canada
Fundersnot available
KeywordsDried blood spotAntibodyBeadImmunoassayChromatographyDried bloodMicrosphereHuman immunodeficiency virus (HIV)Computer scienceBiomedical engineeringMedicineMaterials scienceChemistryVirologyImmunology

Abstract

fetched live from OpenAlex

Simultaneous multianalyte immunoassays offer advantages, including reduction of technical operations, execution time, and overall costs. The suspension array technology (SAT), which uses microfluorospheres with flow cytometry, is a multianalyte immunoassay that requires small specimen volumes, such as those obtained by less-invasive blood sampling approaches such as heel or finger sticks, as well as those obtained in pediatric specimens. The dried-blood-spot (DBS) technology has become an important screening tool for clinical and epidemiologic testing (1)(2)(3). It is particularly convenient in rural, resource-limited settings where trained personnel and adequate facilities for blood collection, processing, transport, and storage may not be available. This approach, however, provides limited specimen volume (∼5–6 μL of serum/6-mm punch) (2). Fortunately, SAT is well suited to support such a format (4)(5). The range of applications for SAT includes antibody, oligonucleotide, peptide, and protein bead arrays (PBAs) (4)(6)(7)(8)(9)(10)(11)(12)(13)(14)(15)(16)(17). PBAs have been used for the simultaneous detection of serum antibodies to infectious agents for systemic candidiasis (18), herpes viruses (19), measles, mumps (20), and HIV (21)(22). The successful detection of HIV-1 serum antibodies by a four-protein bead array was first reported by Scillian et al. (21), who used beads of various sizes and proteins noncovalently coupled to beads. Reagents are now available that permit covalent coupling of proteins to beads and simultaneous analysis of up to 100 color-coded bead sets in a high-throughput, 96-well plate format. In addition, a new generation of flow cytometers compatible with SAT has recently been introduced, e.g., the Luminex-100 System (Luminex Corp.) and the FACSArray (BD Biosciences). We have developed and evaluated a HIV-1 PBA for the rapid detection of antibodies to seven viral proteins from fresh plasma and DBS specimens.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.012
Threshold uncertainty score0.039

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0010.001
Science and technology studies0.0000.000
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0120.012

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.019
GPT teacher head0.253
Teacher spread0.234 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations26
Published2004
Admission routes2
Has abstractyes

Explore more

Same venueClinical Chemistry→Same topicBiosensors and Analytical Detection→French-language works237,207→