MétaCan
Menu
Back to cohort
Record W2178375864 · doi:10.1109/jmems.2015.2467389

A Two-Row Interdigitating-Finger Repulsive-Torque Electrostatic Actuator and Its Application to Micromirror Vector Display

2015· article· en· W2178375864 on OpenAlex

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

affAt least one author lists a Canadian institution in the pinned OpenAlex snapshot.

Bibliographic record

VenueJournal of Microelectromechanical Systems · 2015
Typearticle
Languageen
FieldEngineering
TopicAdvanced MEMS and NEMS Technologies
Canadian institutionsToronto Metropolitan University
Fundersnot available
KeywordsActuatorRotation (mathematics)OpticsTorqueVoltageBeam (structure)Rotary actuatorPhysicsControl theory (sociology)EngineeringComputer scienceElectrical engineeringArtificial intelligence

Abstract

fetched live from OpenAlex

This paper presents a novel two-row interdigitating-finger repulsive-torque electrostatic actuator and its application to the micromirror vector display. The actuator consists of upper and lower rotation units and an output beam. Each unit has one row of rotation fingers, i.e., the lower and upper rotation fingers, which interdigitate with each other. The lower and upper rotation fingers are subject to different electric potentials. Each rotation finger and its underneath aligned fixed finger are subject to the same electric potential. The actuator generates repulsive torques to rotate the lower and upper fingers out-of-plane with the maximum rotation not limited either by the gap between fingers and the substrate nor by the pull-in effect. The output beam is connected to the lower row of rotation fingers, and therefore, the actuator has the same rotation as the lower unit. The actuator requires only two thin films and is suitable for surface micromachining. The model is established to verify the actuator and calculate its performance. Prototypes are fabricated and tested. The experimental results show that the actuator achieved a mechanical rotation of 11.5° at the static driving voltage of 150 V and a resonant frequency of 380 Hz with a sinusoidal driving voltage varying from 20 to 70 V. This paper demonstrates the application of the actuator in micromirror vector display. Four actuators are connected to the peripheries of a micromirror plate and independently controlled to drive the mirror plate to achieve quasi-static 2-D rotation. A laser beam is reflected and steered by the mirror plate to any desired direction to realize vector display. The prototype of the vector display micromirror is fabricated and tested. A vector display module integrating the micromirror, a laser, and a concave lens is built. Based on this module, an automotive head-up display system is developed, which is able to display the navigation map, speed, turning sign, and vehicle location on a translucent screen.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.026
Threshold uncertainty score0.836

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.011
GPT teacher head0.252
Teacher spread0.242 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it