MétaCan
Menu
Back to cohort
Record W2178999423 · doi:10.1021/acs.analchem.5b03209

Nanoflow LC–MS for High-Performance Chemical Isotope Labeling Quantitative Metabolomics

2015· article· en· W2178999423 on OpenAlexafffund
Zhendong Li, Jaspaul Tatlay, Liang Li

Bibliographic record

VenueAnalytical Chemistry · 2015
Typearticle
Languageen
FieldBiochemistry, Genetics and Molecular Biology
TopicMetabolomics and Mass Spectrometry Studies
Canadian institutionsUniversity of Alberta
FundersAlberta InnovatesNatural Sciences and Engineering Research Council of CanadaCanada Research ChairsGenome Canada
KeywordsChemistryChromatographyMetabolomicsMetaboliteMetabolomeAnalyteMass spectrometryLiquid chromatography–mass spectrometryUrineIsotopeBiochemistry

Abstract

fetched live from OpenAlex

Nanoflow liquid chromatography mass spectrometry (nLC-MS) is frequently used in the proteomics field to analyze a small amount of protein and peptide samples. However, this technique is currently not widespread in the metabolomics field. We report a detailed investigation on the development of an nLC-MS system equipped with a trap column for high-performance chemical isotope labeling (CIL) metabolomic profiling with deep coverage and high sensitivity. Experimental conditions were optimized for profiling the amine/phenol submetabolome with (13)C-/(12)C-dansylation labeling. Comparison of analytical results from nLC-MS and microbore LC-MS (mLC-MS) was made in the analysis of metabolite standards and labeled human urine and sweat samples. It is shown that, with a 5-μL loop injection, 7 labeled amino acid standards could be detected with S/N ranging from 7 to 150 by nLC-MS with an injection of 5 nM solution containing a total of 25 fmol labeled analyte. For urine metabolome profiling where the sample amount was not limited, nLC-MS detected 13% more metabolites than mLC-MS under optimal conditions (i.e., 4524 ± 37 peak pairs from 26 nmol injection in triplicate vs 4019 ± 40 peak pairs from 52 nmol injection). This gain was attributed to the increased dynamic range of peak detection in nLC-MS. In the analysis of human sweat where the sample amount could be limited, nLC-MS offered the advantage of providing much higher coverage than mLC-MS. Injecting 5 nmol of dansylated sweat, 3908 ± 62 peak pairs or metabolites were detected by nLC-MS, while only 1064 ± 6 peak pairs were detected by mLC-MS. Because dansyl labeled metabolites can be captured on a reversed phase (RP) trap column for large volume injection and are well separated by RPLC, the CIL platform can be readily implemented in existing nLC-MS instruments such as those widely used in shotgun proteomics.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.033
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.028
GPT teacher head0.282
Teacher spread0.254 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations35
Published2015
Admission routes2
Has abstractyes

Explore more

Same venueAnalytical ChemistrySame topicMetabolomics and Mass Spectrometry StudiesFrench-language works237,207