MétaCan
Menu
Back to cohort
Record W2187306276 · doi:10.82308/46382

Analysis of acidity in oil-based matrices by infrared spectroscopy

2010· article· en· W2187306276 on OpenAlexfundno aff
Yue Li

Bibliographic record

VenueeScholarship@McGill (McGill) · 2010
Typearticle
Languageen
FieldChemistry
TopicSpectroscopy and Chemometric Analyses
Canadian institutionsnot available
FundersNatural Sciences and Engineering Research Council of CanadaMcGill University
KeywordsInfrared spectroscopyInfraredChemistrySpectroscopyAnalytical Chemistry (journal)Environmental chemistryOrganic chemistryPhysicsOptics

Abstract

fetched live from OpenAlex

La praticabilité d'utiliser un spectromètre infrarouge portatif comportant un filtre variable superposé à une barrette de détecteurs (dénommé un spectromètre VFA IR) et équipé d'une cellule d'écoulement de transmission pour analyser quantitativement les huiles de table pour leur teneur en acide gras libre (AGL) a été évaluée. L'approche à la détermination de la teneur en AGL a été basée sur une méthode précédemment élaborée sur un spectromètre infrarouge à transformée de Fourier (IRTF) qui implique l'extraction des AGL dans le méthanol contenant le cyanamide d'hydrogène de sodium, qui convertit les AGL en leurs sels, suivie de la mesure de l'absorbance de carboxylate à 1571 cm-1 dans le spectre de la phase de méthanol. L'Énergie fournie par la source pulsée relativement faible du spectromètre VFA IR s'est avérée insuffisante pour la mesure précise de l'absorption de carboxylate superposée à l'absorption forte de méthanol à 1450 cm-1. En changeant le dissolvant d'extraction en éthanol, de bons spectres et des courbes d'étalonnage ayant un écart-type global de ±0.07% AGL ont pu être obtenus. Ce travail a à son tour mené à la recherche sur l'utilisation d'une solution d'éthanol et de NaHNCN comme réactif de transduction de signal pour une analyse de nombre acide (NA) en huiles lubrifiantes à base minérale, par lequel l'acidité totale soit mesurée par la diminution de l'absorption νC≡N du NaHNCN à 2109 cm-1 comme résultat de la réaction acide-base. La réponse équivalente de l'absorption νC≡N aux acides inorganiques forts et à l'acide oléique a démontré que le NaHNCN, une base légèrement plus faible que le KOH, ionise entièrement les acides organiques. Des solutions étalons ont été préparées par l'addition directe de l'acide oléique à la solution de NaHNCN/éthanol, et une équation de calibrage pour la détermination de NA a été obtenue par un ajustement quadratique des données de co

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.005

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.000
Science and technology studies0.0000.000
Scholarly communication0.0010.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0010.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.010
GPT teacher head0.251
Teacher spread0.241 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations2
Published2010
Admission routes1
Has abstractyes

Explore more

Same venueeScholarship@McGill (McGill)Same topicSpectroscopy and Chemometric AnalysesFrench-language works237,207