MétaCan
Menu
Back to cohort
Record W2189291174 · doi:10.7863/jum.2005.24.10.1391

Accuracy and Outcome of Sonographically Guided Intra-articular Sodium Hyaluronate Injections in Patients With Osteoarthritis of the Hip

2005· article· en· W2189291174 on OpenAlex

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

aboutThe title or abstract carries a Canadian signal from the geographic lexicon.
no affNo Canadian affiliation: this work is invisible to an affiliation-only frame.
No Canadian affiliation. An affiliation-only frame, the usual design, would never have seen this work. It is one of the works that make the case for inverting the frame.

Bibliographic record

VenueJournal of Ultrasound in Medicine · 2005
Typearticle
Languageen
FieldMedicine
TopicOsteoarthritis Treatment and Mechanisms
Canadian institutionsnot available
Fundersnot available
KeywordsMedicineSodium hyaluronateOsteoarthritisVisual analogue scaleProspective cohort studySurgeryRadiologyNuclear medicine

Abstract

fetched live from OpenAlex

OBJECTIVE: The aim of this study was to evaluate the accuracy and outcome of sonographically guided intra-articular sodium hyaluronate injections in patients with osteoarthritis of the hip. METHODS: The prospective study involved 10 patients who had the diagnosis of unilateral hip osteoarthritis. The mean age of the patients was 63.2 years (range, 27-80 years). Depending on patient body weight, either a 3.5- to 5-MHz convex transducer or a 5- to 12-MHz linear transducer was used to examine each affected joint. Every subject received 3 injections of sodium hyaluronate, 1 per week for 3 consecutive weeks. With real-time sonographic monitoring, each joint was penetrated with a 20-gauge Chiba needle. Contrast medium was injected initially, and proper intra-articular placement was verified with computed tomography before the hyaluronate injection. Each patient's outcome was assessed on the basis of visual analog scale results and Western Ontario and McMaster Universities osteoarthritis index findings that were recorded before the set of injections and 2, 4, and 6 months after the third injection. RESULTS: Computed tomography confirmed accurate placement in all 30 injections in the study. The visual analog scale and the Western Ontario and McMaster Universities osteoarthritis index scores showed that 80% of the patients had less pain in the joint at 6 months after the last injection. CONCLUSIONS: Sonographically guided intra-articular injection of sodium hyaluronate for patients with hip osteoarthritis is easy to perform and is a safe, economical, and well-tolerated form of treatment. In contrast to fluoroscopic or computed tomographic guidance, the sonographic technique exposes neither the patient nor the physician to radiation.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.036
Threshold uncertainty score0.355

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.011
GPT teacher head0.261
Teacher spread0.250 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it