MétaCan
Menu
Back to cohort
Record W2200713404 · doi:10.3747/co.22.2727

Para-Aortic and Pelvic Extended-Field Radiotherapy for Advanced-Stage Uterine Cancer: Dosimetric and Toxicity Comparison between the Four-Field Box and Intensity-Modulated Techniques

2015· article· en· W2200713404 on OpenAlexaffvenue
Alex Rabinovich, Laurence Bernard, Agnihotram V. Ramanakumar, Gabriela Stroian, Walter H. Gotlieb, Susie Lau, Boris Bahoric

Bibliographic record

VenueCurrent Oncology · 2015
Typearticle
Languageen
FieldMedicine
TopicEndometrial and Cervical Cancer Treatments
Canadian institutionsMcGill University Health CentreMcGill UniversityJewish General Hospital
FundersBen-Gurion University of the NegevAmerican Physicians Fellowship for Medicine in IsraelIsrael Cancer AssociationIsrael Cancer Research Fund
KeywordsMedicineStage (stratigraphy)Genitourinary systemRectumRadiation therapyEndometrial cancerPelvisUrologyCancerRadiologyNuclear medicineOncologyInternal medicine

Abstract

fetched live from OpenAlex

BACKGROUND: In patients with advanced-stage endometrial carcinoma (eca), extended-field radiotherapy (efrt) is traditionally delivered by the 3-dimensional conformal (3d-crt) 4-field box technique. In recent years, the use of intensity-modulated radiotherapy (imrt) in gynecologic cancers has increased. We compared the delivery of efrt by the 3d-crt and contemporary imrt techniques. METHODS: After surgical staging and adjuvant chemotherapy in 38 eca patients, efrt was delivered by either imrt or 3d-crt. Doses to the organs at risk, side effects, and outcomes were compared between the techniques. RESULTS: Of the 38 eca patients, 33 were stage iiic, and 5 were stage ivb. In the imrt group, maximal doses to rectum, small intestine, and bladder were significantly higher, and mean dose to bladder was lower (p < 0.0001). Most acute gastrointestinal, genitourinary, and hematologic side effects were grade i or ii and were comparable between the groups. In long-term follow-up, only grade 1 cystitis at 3 months was statistically higher in the imrt patients. No grade iii or iv gastrointestinal or genitourinary toxicities were observed. No statistically significant differences in overall and disease-free survival or recurrence rates were observed between the techniques. CONCLUSIONS: In advanced eca patients, imrt is a safe and effective technique for delivering efrt to the pelvis and para-aortic region, and it is comparable to the 3d-crt 4-field box technique in both side effects and efficacy. For centres in which imrt is not readily available, 3d-crt is a valid alternative.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.004

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.150
GPT teacher head0.459
Teacher spread0.309 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations3
Published2015
Admission routes2
Has abstractyes

Explore more

Same venueCurrent OncologySame topicEndometrial and Cervical Cancer TreatmentsFrench-language works237,207