Efficacy and safety of fluticasone furoate/vilanterol or tiotropium in subjects with COPD at cardiovascular risk
Bibliographic record
Abstract
BACKGROUND: Fluticasone furoate/vilanterol (FF/VI) is a novel, once-daily, inhaled corticosteroid/long-acting β2-agonist combination approved for the treatment of COPD and asthma. We compared the safety and efficacy of FF/VI and tiotropium (TIO) in subjects with moderate-to-severe COPD with greater risk for comorbid cardiovascular disease (CVD). METHODS: This randomized, blinded, double-dummy, parallel-group study compared a once-daily morning dose of FF/VI 100/25 mcg delivered via ELLIPTA™ with TIO 18 mcg via HandiHaler(®) for 12 weeks in subjects with diagnosed COPD, forced expiratory volume in 1 second (FEV1) 30%-70% predicted, and CVD or CVD risk. The primary endpoint was change from baseline in 24-hour weighted mean FEV1 on Day 84. Other efficacy endpoints included time to onset of bronchodilation, trough FEV1, other spirometry measures, rescue medication use, symptoms, quality of life (St George's Respiratory Questionnaire-COPD [SGRQ-C]), and health status (COPD Assessment Tests [CAT]) measures. Safety endpoints included cardiovascular monitoring, cortisol excretion, COPD exacerbations, and adverse events, including prespecified drug effects. RESULTS: Both FF/VI and TIO improved the 24-hour weighted mean FEV1 from baseline after 12 weeks with no significant difference between treatments. Other endpoints favored FF/VI for time to onset of bronchodilation, rescue medication use, dyspnea, SGRQ-C and CAT scores, or favored TIO for change from baseline in forced vital capacity and inspiratory capacity. Pneumonia occurred more frequently in the FF/VI group, and two TIO-treated subjects died following cardiovascular events. Other safety measures were similar between groups, and cardiovascular monitoring did not reveal increased CVD risk. CONCLUSION: Both FF/VI and TIO were efficacious in improving lung function in subjects with COPD and comorbid CVD or CVD risk factors, with minor differences in efficacy and safety profiles.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.001 | 0.000 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.001 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.000 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one teacher head, not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".