MétaCan
Menu
Back to cohort
Record W2203621251 · doi:10.5301/hip.2008.3440

Cement as a locking mechanism for screw heads in acetabular revision shells a biomechanical analysis

2008· article· en· W2203621251 on OpenAlexaff
G. Yves Laflamme, Ghassan Alami, Fouad Zhim

Bibliographic record

VenueHip International · 2008
Typearticle
Languageen
FieldMedicine
TopicOrthopaedic implants and arthroplasty
Canadian institutionsPolytechnique MontréalUniversité de Montréal
Fundersnot available
KeywordsMedicineAcetabulumMechanism (biology)OrthodonticsBiomechanicsCementDentistrySurgeryAnatomyComposite materialMaterials science

Abstract

fetched live from OpenAlex

In acetabular revisions, polyethylene (PE) liners are often cemented into metal shells on top of acetabular screw heads. This study investigates the possibility of using this technique to obtain fixed-angle acetabular screws Eth a concept that has not yet been reported in the literature. Two groups of screws (n=8) were inserted into Trabecular Metal revision shells (Zimmer), into which PE liners were then cemented. Screws in Group 1, inserted in the shell's pre-fabricated holes, were countersunk, whereas screws in Group 2 were inserted in custom-drilled holes that make their heads protrude into, and interdigitate with, the overlying cement mantle. Perpendicular loading was then applied to the screw shafts both statically to failure and cyclically. A greater stiffness was observed for the protruding screws upon static loading; and while the countersunk screws all failed at the screw-cement junction (53.44 + or - 8.33 N), the protruding screws all failed at the screw shaft (1049.79 + or - 32.12 N) a 20-fold difference (p< 0.05). Under cyclic loading, only the protruding screw head specimen did not fail, undergoing an overall displacement within the limits of osseointegration.These results support the hypothesis that the protrusion of an acetabular screw head into an overlying cement mantle significantly increases its angular stability. Provided other variables are favorable, this locking effect may increase the initial stability of the whole implant, thus improving the ultimate success of complex acetabular revisions.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.002
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.003

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.002
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.000
Science and technology studies0.0000.001
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.036
GPT teacher head0.318
Teacher spread0.282 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations12
Published2008
Admission routes1
Has abstractyes

Explore more

Same venueHip InternationalSame topicOrthopaedic implants and arthroplastyFrench-language works237,207