Wavefront-guided LASIK for Myopia: Effect on Visual Acuity, Contrast Sensitivity, and Higher Order Aberrations
Why this work is in the frame
A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.
Bibliographic record
Abstract
PURPOSE: To determine the impact of wavefront-guided LASIK for myopia with or without astigmatism on high and low contrast best spectacle-corrected visual acuity (BSCVA), photopic and mesopic contrast sensitivity, and higher order aberrations. METHODS: Bilateral wavefront-guided LASIK (LADAR-Vision4000; Hansatome microkeratome) was performed on 324 eyes (162 patients) with a mean spherical manifest refraction of -2.84 +/- 1.35 diopters (D) (range: -0.25 to -6.50 D) and astigmatism of -0.81 +/- 0.74 D (range: 0 to -4.00 D). Mean age was 37.7 +/- 9.3 years (range: 20 to 60 years). Best spectacle-corrected visual acuity and contrast sensitivity were assessed using ETDRS charts and vertical sinusoidal gratings, respectively. Higher order aberrations were measured using a Shack-Hartmann wavefront sensor, analyzed across a 5-mm pupil. Repeated measures and post hoc analyses determined statistical significance (P < .0025). Only right eyes were analyzed. RESULTS: One hundred thirty-six eyes (84%) had uncorrected visual acuity of 20/20 or better 6 months postoperative; 80.9% (131 eyes) were within +/- 0.50 D of attempted correction. Statistically significant postoperative improvements were noted in high and low contrast BSCVA (both P < or = .001); in photopic contrast sensitivity at 3, 6, and 12 cycles per degree (cpd); and in mesopic contrast sensitivity at 12 and 18 cpd (all P < .001). With respect to higher order aberrations, a statistically significant change was seen in Zernike coefficients Z3(-1), Z3(1), Z3(-3), Z3(3), and Z4(4) following surgery (range of mean absolute change: 0.042 to 0.142 microm; all P < or = .001). All increased in magnitude except for Z3(-3), which decreased. CONCLUSIONS: Despite an increase in higher order aberrations, wavefront-guided LASIK yields excellent visual acuity and contrast sensitivity. Spherical aberration, which increases the most following non-wavefront-guided LASIK, showed no significant change.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.001 | 0.001 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.001 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.000 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it