MétaCan
Menu
← Back to cohort
Record W2217329351 · doi:10.1149/ma2015-02/14/703

Localized Corrosion of Carbon Steel in the Presence of Gamma Radiation

2015· article· en· W2217329351 on OpenAlexaffabout
J.C. Wren, Linda Wu, Dan Guo, Alexander Van Belois, James J. Noël, Peter Keech

Bibliographic record

VenueECS Meeting Abstracts · 2015
Typearticle
Languageen
FieldMaterials Science
TopicHydrogen embrittlement and corrosion behaviors in metals
Canadian institutionsNuclear Waste Management OrganizationWestern University
Fundersnot available
KeywordsCorrosionCrevice corrosionPipingMaterials scienceMetallurgyWeldingCarbon steelRadiolysisIrradiationEnvironmental scienceEnvironmental engineering

Abstract

fetched live from OpenAlex

Canada’s long-term plan for used nuclear fuel includes permanent disposal in a deep geological repository (DGR) using a multiple-barrier system with a key barrier being the used fuel container (UFC). The UFC design consists of an inner vessel of carbon steel (CS), which provides the structural strength to withstand repository loads, and an outer layer of copper, which functions as an external corrosion barrier. The inner vessel of the current UFC design is composed of a pressure grade CS hemispherical head and pressure grade CS piping as a body, the two parts to be laser welded on-site. One of potential issues with this design is the effect of g-radiation on corrosion of the crevice near the weld region. The environment inside the sealed UFC would be humid air. Gamma-irradiation of humid air produces NOx and HNO3, and these species could accelerate the formation and condensation of water droplets in crevices (which might also have surface roughness features that act as preferential condensation sites). The chemical environment in such acidic condensed water, coupled with the presence of oxidizing water radiolysis products, could be very aggressive. Corrosion within the crevice between the head and the body of the container assembly or in the stressed regions near the welds could lead to a localized build-up of corrosion products (oxide deposits and H2gas). The effect of g-radiolysis on crevice corrosion of CS is being investigated using a combination of corrosion exposure tests and electrochemical measurements. These measurements are augmented by post-test analysis of oxide surface using SEM, XPS and Raman spectroscopy. In the corrosion tests reported here, a prepared CS crevice was wetted by adding a couple of water droplets to the mouth of the crevice. The test sample was then exposed to a desired environment in a sealed container for 20 h. Optical images of the corroded surfaces show that the corrosion of the wet bold surface progresses more extensively in air than in Ar, more at 80 oC than at 25 oC and more in the presence rather than in the absence of radiation. The composition of the oxide formed on the wet bold surface (as determined by Raman spectroscopy) shows the oxidation leads to formation of a mixed FeII/FeIII oxide/hydroxide in Ar, and to the formation of FeIII oxyhydroxide and FeIII oxide in addition to the FeII/FeIII oxide in air. Increasing temperature increases the ratio of oxide to hydroxide or oxyhydroxide but does not affect the metal oxidation states. More corrosion products are formed in the presence than absence of radiation. In contrast to the bold surface the interior surface of crevice remained smooth. The XPS analysis of the crevice surface indicates that the oxides formed there are thin (< ~ 9 nm) and that a larger fraction of the oxide is FeIII oxide/hydroxide rather than FeII/FeIII oxide. The thickness of the oxide formed at 80 oC is slightly higher than that formed at 25 oC. Radiation slightly decreases the oxide thickness at 25 oC while it increases the oxide thickness at 80 oC. The different corrosion behaviours of the crevice and bold surfaces raise the possibility of galvanic coupling between the two surfaces. This galvanic effect was investigated by monitoring the coupling current between two electrodes, one electrode representing the bold surface and the other representing the crevice surface, in the electrochemical coupling tests. To aid in interpretation of the galvanic coupling experiments, the corrosion potential and linear polarization measurements were made on each electrode separately. The post-test surfaces from these tests were examined by SEM and XPS. The observed effects of temperature and g-radiation on the corrosion potentials are consistent with the different oxide formation and growth observed in the coupon exposure study. The corrosion potential on the crevice electrode is always slightly higher than that of a bold electrode with the difference depending on temperature and radiation environment. A galvanic coupling current observed between the two electrodes shows that the crevice electrode is the net cathode. The measured coupling currents are consistent with the results from the dynamic polarization tests performed on each electrode. A CS crevice corrosion mechanism that can explain both the crevice corrosion tests and the electrochemical results is discussed.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.043
Threshold uncertainty score0.086

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.034
GPT teacher head0.283
Teacher spread0.250 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2015
Admission routes2
Has abstractyes

Explore more

Same venueECS Meeting Abstracts→Same topicHydrogen embrittlement and corrosion behaviors in metals→French-language works237,207→