MétaCan
Menu
Back to cohort
Record W2219317627 · doi:10.1364/oe.23.020540

Compact multi-channel surface plasmon resonance sensor for real-time multi-analyte biosensing

2015· article· en· W2219317627 on OpenAlexfundno aff
Yun Liu, Shimeng Chen, Qiang Liu, Jean‐François Masson, Wei Peng

Bibliographic record

VenueOptics Express · 2015
Typearticle
Languageen
FieldBiochemistry, Genetics and Molecular Biology
TopicAdvanced Biosensing Techniques and Applications
Canadian institutionsnot available
FundersMinistry of Education of the People's Republic of ChinaNatural Sciences and Engineering Research Council of CanadaNational Natural Science Foundation of China
KeywordsBiosensorAnalyteSurface plasmon resonanceMaterials scienceMultiplexingOpticsRefractive indexRefractometryOptoelectronicsNanotechnologyChemistryNanoparticleComputer scienceChromatographyPhysics

Abstract

fetched live from OpenAlex

A compact multi-channel surface plasmon resonance (SPR) biosensor is demonstrated based on a tablet as the measurement platform. The SPR biosensor employs a bundle of fiber-optic SPR sensors as the multiplexed sensing elements that are illuminated by a light-emitting diode (LED) plane light source and detected by a cordless camera. The multi-channel SPR biosensor was based on optical fiber components for precise, label-free and high-throughput detection without the use of complex, specialized or fragile instrumentation that would require optical calibration. The reference and control channels compensated for the fluctuation of the LED light source and the bulk refractive index, increasing the accuracy and reliability of the biosensor. The multi-channel SPR biosensor was applied for multi-analyte biosensing of immunoglobulin G (IgG) and concanavalin A (Con A). The channels functionalized with staphylococcal protein A (SPA) and ribonuclease B (RNase B) only showed relative intensity responses to their corresponding analytes. Moreover, the multi-channel SPR sensors responded to the specific detection of IgG and Con A with an approximately linear relative intensity response to the analyte concentration. Hence, multiple analytes were simultaneously and quantitatively detected with the multi-channel SPR biosensor. This compact, cost-effective multi-channel SPR biosensor is adapted for point-of-care tests, which are important in healthcare and environmental monitoring and for biomolecular interaction analysis.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.001
Threshold uncertainty score0.004

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0010.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.050
GPT teacher head0.322
Teacher spread0.272 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations43
Published2015
Admission routes1
Has abstractyes

Explore more

Same venueOptics ExpressSame topicAdvanced Biosensing Techniques and ApplicationsFrench-language works237,207