MétaCan
Menu
Back to cohort
Record W2242621671

Development of a calibration procedure for integration of dual fluoroscopy and motion analysis

2013· article· en· W2242621671 on OpenAlexaffvenueabout
Braden Mund

Bibliographic record

VenueJournal of undergraduate research in Alberta · 2013
Typearticle
Languageen
FieldMedicine
TopicShoulder Injury and Treatment
Canadian institutionsUniversity of Calgary
Fundersnot available
KeywordsKinematicsComputer scienceArtifact (error)CalibrationComputer visionMotion captureArtificial intelligenceFluoroscopyGait analysisGaitJoint (building)Frame (networking)Motion analysisMotion (physics)SimulationEngineeringMathematicsMedicinePhysicsTelecommunications
DOInot available

Abstract

fetched live from OpenAlex

INTRODUCTION Accurate quantification of in vivo effects of injury on joint mechanics is essential to identify movement abnormality and related joint pathologies such as osteoarthritis. Typically used Motion Analysis (MA) technologies for studying human gait and injury suffer from soft tissue movement artifact, which may prohibit identification of small but significant changes of joint motion. High-speed dual fluoroscopy (DF) systems such as the one at the Clinical Movement Assessment Laboratory, University of Calgary, provide movement-artifact-free, high-resolution (0.30-0.44°, 0.25-0.33mm) [1], in vivo bone kinematics during dynamic activities. Such systems however, represent a trade-off between high system accuracy and limited field of view (FOV~10 inch) [2] compared to MA systems. DF systems therefore typically provide information only for a single joint while MA systems may capture the whole body. This project worked toward the integration of traditional MA and state-of-the-art DF systems to provide high accuracy joint as well as lower limb kinematics. The aim was to create hardware and software solutions for the calibration of a DF system for integration with MA systems. METHODS A Plexiglas calibration frame (48” x 22”) with an integrated steel bead grid (95 x 41, 0.125″ diameter) was designed and built. The calibration frame pattern spanned the entire frame to allow easy identification of the pattern in the small FOV of the X-ray images. A unique braille design with letters for each row and column was implemented to support simple bead location identification and future automated procedures. Three sets of column identifiers were placed at the left, center, and right regions. This pattern was glued into the calibration frame using 0.125 diameter spherical steel beads. The DF 3D coordinates were determined by imaging a custom calibration cube and using a modified direct linear transform [3]. The calibration frame was placed on top of the treadmill and images were acquired by the DF system. A MATLAB program was developed to process the calibration frame images. A Hough Transform-based circle detection function was used for digitizing the beads in both images. The user then identified the bead ID’s in the X-ray images. Combining the X-ray image bead locations, the DF 3D coordinate system, and the calibration frame’s physical parameters, the planar equation for the treadmill location can be computed. RESULTS Figure 1 shows an image of the calibration device positioned on the treadmill, as well as the resulting X-ray images. The braille pattern was successful in allowing the user to identify the pattern and its beads. DISCUSSION AND CONCLUSIONS The calibration frame developed in provides information of the spatial location of the instrumented treadmill. This is instrumental for integrating the DF and MA systems. Without this calibration device, all joint movements are observed as floating in 3D space and information about the joint’s interaction with the ground is not accessible. Further, without systems integration, no knowledge is available for the interaction of multiple joints of the lower limbs, which contains critical information for biomechanical investigations of injury and disease. Future developments based on these methods will provide the planar equations of the treadmill to provide full systems integration.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.166
Threshold uncertainty score0.225

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.079
GPT teacher head0.404
Teacher spread0.325 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2013
Admission routes3
Has abstractyes

Explore more

Same venueJournal of undergraduate research in AlbertaSame topicShoulder Injury and TreatmentFrench-language works237,207