MétaCan
Menu
Back to cohort
Record W2249208421

Mass Transfer Studies of Carbon Dioxide Absorption into Aqueous Solutions of 4-(Diethylamine)-2-Butanol, Blended Monoethanolamine with 4-(Diethylamine)-2-Butanol, and Blended Monoethanolamine with Methyldiethanolamine

2013· dissertation· en· W2249208421 on OpenAlexfundno aff
Abdulaziz Naami

Bibliographic record

VenueoURspace (University of Regina) · 2013
Typedissertation
Languageen
FieldEngineering
TopicCarbon Dioxide Capture Technologies
Canadian institutionsnot available
FundersFaculty of Graduate Studies and Research, University of AlbertaNatural Sciences and Engineering Research Council of CanadaCanadian Bureau for International Education
KeywordsDiethylamineButanolCarbon dioxideAqueous solutionChemistryAbsorption (acoustics)Organic chemistryMaterials scienceEthanol
DOInot available

Abstract

fetched live from OpenAlex

One of the parameters used to characterize the performance of a solvent for carbon dioxide (CO2) capture is the mass transfer performance of CO2 absorption in the solvent. In this study, a newly developed amino alcohol solvent, 4-(diethylamino)-2-butanol (DEAB), was evaluated for its mass transfer performance as a single or blended solvent in comparison with existing commercially available amine solvents. Consequently, the mass transfer performance characteristics of the absorption of CO2 in aqueous solutions of a primary alkanolamine (e.g. monoethanolamine, MEA), a tertiary amine (e.g. methyldiethanolamine, MDEA) and DEAB were compared using a bench-scale absorber packed with high efficiency DX structured packing at atmospheric pressure using a feed gas mixture containing 14.9% CO2 and 85.1% nitrogen. The mass transfer performance characteristics of CO2 absorption in aqueous blended MDEA/MEA solution with total concentrations of 30 g/L and weight ratios of 27/03, 25/05, and 23/07, as well as aqueous blended DEAB/MEA solution with concentrations of DEAB+MEA (g/L) of 3.5+30.23, 7.18+30.23, 14.43+30.23, 17.96+30.23, 21.82+30.23, 25.15+30.32, and 29.38+30.23 were also compared using the same experimental conditions. Specific absorption performance criteria used for this study were CO2 removal efficiency, absorber height requirement, the effective interfacial area for mass transfer, and the overall mass transfer coefficient (KGav). The results show that the new tertiary aqueous chemical solvent, DEAB, has a much higher removal efficiency for CO2 along the height of the column than aqueous MDEA, another tertiary solvent. The results for blended aqueous MDEA/MEA system and blended aqueous DEAB/MEA system showed that the ratios of 23/07 (g/L) MDEA/MEA system and 17.96/30.23 of DEAB/MEA system respectively has the highest CO2 removal efficiencies along the height of the column, highest KGav values and highest cyclic capacities compared with other ratios tested, with the blended aqueous DEAB/MEA system having extremely superior performance. Interestingly, the results of the new blended amine solution demonstrate that the height of the column can be reduced substantially by up to 32.5% compared even to pure aqueous MEA (30.23 g/L), which before now, has been credited with providing the shorter column height.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow), Research integrity
Consensus categoriesMeta-epidemiology (narrow)
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.096
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0030.000
Bibliometrics0.0020.002
Science and technology studies0.0000.002
Scholarly communication0.0000.001
Open science0.0010.000
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.011
GPT teacher head0.201
Teacher spread0.190 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; both teacher heads agree on what is shown here.

Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations15
Published2013
Admission routes1
Has abstractyes

Explore more

Same venueoURspace (University of Regina)Same topicCarbon Dioxide Capture TechnologiesFrench-language works237,207