Combinations of Ethylene Sulfite (ES) and Vinylene Carbonate (VC) As Electrolyte Additives in Li(Ni<sub>1/3</sub>Mn<sub>1/3</sub>Co<sub>1/3</sub>)O<sub>2</sub>/Graphite Pouch Cells
Bibliographic record
Abstract
Introduction Electrolyte additives can be used to improve the lifetime of a Li-ion cell [1]. Electrolyte additives are believed to function by forming or modifying a solid electrolyte interface (SEI) layer on the surface of the positive or negative electrode thus impacting the cycle life, calendar life and safety of Li-ion cells. Ethylene sulfite (ES) has been widely studied by many researchers and has been regarded as an effective SEI-forming additive, especially in PC based electrolytes. Wrodnigg et al. [2] found the introduction of 5 vol % ES to a PC-based electrolyte could suppress or even prevent PC co-intercalation into graphite. Ota et al [3] suggested that when ES was used as an electrolyte additive, the SEI film on the graphite anode contained both inorganic materials like Li2SO3 and organic materials like ROSO2Li. The bulk of the studies on ES have focused upon its effect on the carbon electrode. In this presentation, a detailed study of ES and/or VC as electrolyte additives for Li[Ni1/3Mn1/3Co1/3]O2/graphite pouch cells was investigated using UHPC [4] and a precision storage system at Dalhousie University [5]. Gas evolution during formation and cycling, coulombic efficiency (CE) and charge endpoint capacity slippage during cycling as well as charge transfer resistance before and after cycling were examined and compared. Experimental Dry Li[Ni1/3Mn1/3Co1/3]O2 (NMC)/graphite pouch cells (225 mAh) were obtained from Whenergy (Shandong, China). Before electrolyte filling, the cells were cut just below the heat seal and dried at 80°C under vacuum for 14 h to remove any residual water. Then the cells were transferred immediately to an argon-filled glove box for filling and vacuum sealing. Cells cycled using the UHPC were tested between 2.8 and 4.2 V at 40.0 ± 0.05 °C using currents corresponding to C/20 for 15 cycles where comparisons were made. Electrochemical impedance spectroscopy (EIS) measurements were conducted on NMC/graphite pouch cells before and after cycling on the UHPC. Results and discussion Figure 1 shows data collected from the UHPC during cycling. Figure 1 shows cells containing 2% VC + ES (1 % or 2 %) can provide similar performance in delta V, coulombic efficiency and charge endpoint capacity slippage to cells containing 2% VC. Figure 2 shows the Nyquist plots for NMC/graphite pouch cells with different amounts of ES and/or VC after formation and after UHPC cycling measured at 3.80 V and 10°C. Figure 2 shows that cells containing only ES show obvious impedance growth during cycling. When ES (1% or 2%) is used in combination with VC, the impedance was dramatically decreased both before and after cycling. Cells with 2% VC + 2% ES have the lowest impedance after cycling, only half of that of cells with 2% VC. Therefore, there appear to be significant benefits of the combination of VC and ES for high power cells. References 1. S. S. Zhang, J. Power Sources, 162, 1379 (2006). 2. G. H. Wrodnigg, J. O. Besenhard and M. Winter, J. Electrochem. Soc., 146, 470 (1999). 3. H. Ota, T. Akai, H. Namita, S. Yamaguchi and M. Nomura, J. Power Sources, 119-121, 567 (2011). 4. T. M. Bond, J.C. Burns, D.A. Stevens, H.M. Dahn, and J.R. Dahn, J. Electrochem. Soc., 160 , A521 (2013). 5. N. N. Sinha, T. H. Marks, H. M. Dahn, A. J. Smith, D. J. Coyle, J. J. Dahn and J. R. Dahn, J. Electrochem. Soc., 159, A1672 (2012).
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame machine prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.
Distilled classifier scores by category (both heads)
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.000 | 0.000 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.001 | 0.000 |
| Open science | 0.001 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.001 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".