MétaCan
Menu
Back to cohort
Record W2265360620 · doi:10.1118/1.4941307

Quantifying masking in clinical mammograms via local detectability of simulated lesions

2016· article· en· W2265360620 on OpenAlexafffund
James G. Mainprize, Olivier Alonzo‐Proulx, Roberta A. Jong, Martin J. Yaffe

Bibliographic record

VenueMedical Physics · 2016
Typearticle
Languageen
FieldMedicine
TopicDigital Radiography and Breast Imaging
Canadian institutionsUniversity of TorontoHealth Sciences CentreSunnybrook Health Science Centre
FundersCanadian Cancer Society Research InstituteOntario Institute for Cancer Research
KeywordsDigital mammographyMammographyMasking (illustration)Breast densityCorrelationContrast (vision)Observer (physics)Metric (unit)Nuclear medicineMedicineNoise (video)MathematicsPattern recognition (psychology)Artificial intelligenceComputer sciencePhysicsBreast cancerImage (mathematics)

Abstract

fetched live from OpenAlex

PURPOSE: High mammographic density is known to be associated with decreased sensitivity of mammography. Recent changes in the BI-RADS density assessment address the effect of masking by densities, but the BI-RADS assessment remains qualitative and achieves only moderate agreement between radiologists. An automated, quantitative algorithm that estimates the likelihood of masking of simulated masses in a mammogram by dense tissue has been developed. The algorithm considers both the effects of loss of contrast due to density and the distracting texture or appearance of dense tissue. METHODS: A local detectability (dL) map is created by tessellating the mammograms into overlapping regions of interest (ROIs), for which the detectability by a non-prewhitening observer is computed using local estimates of the noise power spectrum and volumetric breast density (VBD). The dL calculation was validated in a 4-alternative forced-choice observer study on the ROIs of 150 craniocaudal digital mammograms. The dL metric was compared against the inverse threshold contrast, (ΔμT)(-1) from the observer study, the anatomic noise parameter β, the radiologist's BI-RADS density category, and a validated measure of VBD (Cumulus). RESULTS: The mean dL had a high correlation of r = 0.915 and r = 0.699 with (ΔμT)(-1) in the computerized and human observer study, respectively. In comparison, the local VBD estimate had a low correlation of 0.538 with (ΔμT)(-1). The mean dL had a correlation of 0.663, 0.835, and 0.696 with BI-RADS density, β, and Cumulus VBD, respectively. CONCLUSIONS: The proposed dL metric may be useful in characterizing the potential for lesion masking by dense tissue. Because it uses information about the anatomic noise or tissue appearance, it is more closely linked to lesion detectability than VBD metrics.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.696
Threshold uncertainty score0.368

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.001
Science and technology studies0.0000.001
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.050
GPT teacher head0.354
Teacher spread0.303 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations23
Published2016
Admission routes2
Has abstractyes

Explore more

Same venueMedical PhysicsSame topicDigital Radiography and Breast ImagingFrench-language works237,207