MétaCan
Menu
Back to cohort
Record W2272671044 · doi:10.1016/j.carj.2015.07.002

Radiation Dose Survey for Common Computed Tomography Exams: 2013 British Columbia Results

2015· article· en· W2272671044 on OpenAlexafffundabout
Yogesh Thakur, Thorarin A. Bjarnason, Patricia Baxter, Mitch Griffith, Kirk Eaton

Bibliographic record

VenueCanadian Association of Radiologists Journal · 2015
Typearticle
Languageen
FieldMedicine
TopicRadiation Dose and Imaging
Canadian institutionsMinistry of HealthInterior HealthVancouver Coastal HealthUniversity of British Columbia, Okanagan CampusUniversity of British ColumbiaIsland Health
FundersHealth Canada
KeywordsMedicineComputed tomographyMedical physicsRadiation doseNuclear medicineRadiation exposureRadiologyLow Dose RadiationInternal medicine

Abstract

fetched live from OpenAlex

In 2013 Health Canada conducted a national survey of computed tomography (CT) radiation usage. We analysed contributions from all 7 public health authorities in the province of British Columbia, which covered scanner age, number of slices, and common adult protocols (≥ 19 years: 70 ± 20 kg, head, chest, abdomen/pelvis, and trunk). Patient doses were recorded for common protocols. Diagnostic reference levels (DRLs) was calculated using scanner data with >10 patient doses recorded for each protocol. Data was analysed based on image reconstruction (filtered backprojection vs iterative reconstruction [IR] vs IR available but not in use). Provincial response was 92%, with 59 of 64 CT data used for analysis. The average scanner age was 5.5 years old, with 39% of scanners installed between 2008-2013; 78.5% of scanners were multislice (>64 slices), and 44% of scanners had IR available. Overall British Columbia DRLs were: head = 1305, chest = 529, abdomen/pelvis = 819, and trunk = 1225. DRLs were consistent with Health Canada recommendations and other Canadian published values, but above international standards. For sites with IR available, less than 50% used this technology routinely for head, chest and trunk exams. Overall, use of IR reduced radiation usage between 11%-32% compared to filtered backprojection, while sites using IR vs IR available used 30%/43% less radiation for head/chest exams (P < .05). No significant difference was observed for abdomen/pelvis exams (P = .385). With the fast pace of CT technical advancement, DRLs should reflect the technology used, instead of just globally applied to anatomical regions. Federal guidelines should be updated at a higher frequency to reflect new technology. In addition, new technologies must be utilised to optimize image quality vs radiation usage.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.005
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.029
Threshold uncertainty score0.209

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.005
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0030.009
Science and technology studies0.0010.000
Scholarly communication0.0010.000
Open science0.0010.001
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0040.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.034
GPT teacher head0.276
Teacher spread0.242 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations7
Published2015
Admission routes3
Has abstractyes

Explore more

Same venueCanadian Association of Radiologists JournalSame topicRadiation Dose and ImagingFrench-language works237,207