MétaCan
Menu
Back to cohort

Arterial input function placement effect on computed tomography lung perfusion maps.

2016· article· en· W2274250433 on OpenAlexafffund
Laura Jiménez‐Juan, Hatem Mehrez, C. Dey, Shabnam Homampour, Anastasia Oikonomou, Fatima Ursani, Narinder Paul

Bibliographic record

VenuePubMed · 2016
Typearticle
Languageen
FieldMedicine
TopicMRI in cancer diagnosis
Canadian institutionsUniversity Health NetworkUniversity of TorontoSunnybrook Health Science Centre
FundersUniversity of Toronto
KeywordsPerfusionRank correlationSpearman's rank correlation coefficientMedicineNuclear medicinePerfusion scanningLungAnalysis of varianceLinear regressionRadiologyMathematicsInternal medicineStatistics

Abstract

fetched live from OpenAlex

BACKGROUND: A critical source of variability in dynamic perfusion computed tomography (DPCT) is the arterial input function (AIF). However, the impact of the AIF location in lung DPCT has not been investigated yet. The purpose of this study is to determine whether the location of the AIF within the central pulmonary arteries influences the accuracy of lung DPCT maps. METHODS: A total of 54 lung DPCT scans were performed in three pigs using different rates and volumes of iodinated contrast media. Pulmonary blood flow (PBF) perfusion maps were generated using first-pass kinetics in three different AIF locations: the main pulmonary trunk (PT), the right main (RM) and the left main (LM) pulmonary arteries. A total of 162 time density curves (TDCs) and corresponding PBF perfusion maps were generated. Linear regression and Spearman's rank correlation coefficient were used to compare the TDCs. PBF perfusion maps were compared quantitatively by taking twenty six regions of interest throughout the lung parenchyma. Analysis of variance (ANOVA) was used to compare the mean PBF values among the three AIF locations. Two chest radiologists performed qualitative assessment of the perfusion maps using a 3-point scale to determine regions of perfusion mismatch. RESULTS: The linear regression of the TDCs from the RM and LM compared to the PT had a median (range) of 1.01 (0.98-1.03). The Spearman rank correlation between the TDCs was 0.88 (P<0.05). ANOVA analysis of the perfusion maps demonstrated no statistical difference (P>0.05). Qualitative comparison of the perfusion maps resulted in scores of 1 and 2, demonstrating either identical or comparable maps with no significant difference in perfusion defects between the different AIF locations. CONCLUSIONS: Accurate PBF perfusion maps can be generated with the AIF located either at the PT, RM or LM pulmonary arteries.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.004
metaresearch head score (Gemma)0.021
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Methods · Consensus signal: none
Teacher disagreement score0.004
Threshold uncertainty score0.020

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0040.021
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.000
Science and technology studies0.0000.001
Scholarly communication0.0010.001
Open science0.0000.000
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.012
GPT teacher head0.227
Teacher spread0.216 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreMethods

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations2
Published2016
Admission routes2
Has abstractyes

Explore more

Same venuePubMedSame topicMRI in cancer diagnosisFrench-language works237,207