Magnetic resonance imaging for prostate bed radiotherapy planning: An inter‐ and intra‐observer variability study

2015· article· en· W2281302069 on OpenAlexaff
Maroie Barkati, Dany Simard, Daniel Taussky, Guila Delouya

Bibliographic record

VenueJournal of Medical Imaging and Radiation Oncology · 2015
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAdvanced Radiotherapy Techniques
Canadian institutionsUniversité de MontréalHôpital Notre-Dame
Fundersnot available
KeywordsContouringMedicineNuclear medicineMagnetic resonance imagingRadiation therapyProstate cancerRadiation oncologistProstatectomyRadiation treatment planningProstateStandard deviationRadiologyCancerInternal medicine

Abstract

fetched live from OpenAlex

INTRODUCTION: We assessed the inter- and intra-observer variability in contouring the prostate bed for radiation therapy planning using MRI compared with computed tomography (CT). METHODS: We selected 15 patients with prior radical prostatectomy. All had CT and MRI simulation for planning purposes. Image fusions were done between CT and MRI. Three radiation oncologists with several years of experience in treating prostate cancer contoured the prostate bed first on CT and then on MRI. Before contouring, each radiation oncologist had to review the Radiation Therapy Oncology Group guidelines for postoperative external beam radiotherapy. The agreement between volumes was calculated using the Dice similarity coefficient (DSC). Analysis was done using the Matlab software. The DSC was compared using non-parametric statistical tests. RESULTS: Contouring on CT alone showed a statistically significant (P = 0.001) higher similarity between observers with a mean DSC of 0.76 (standard deviation ± 0.05) compared with contouring on MRI with a mean of 0.66 (standard deviation ± 0.05). Mean intra-observer variability between CT and MRI was 0.68, 0.75 and 0.78 for the three observers. The clinical target volume was 19-74% larger on CT than on MRI. The intra-observer difference in clinical target volume between CT and MRI was statistically significant in two observers and non-significant in the third one (P = 0.09). CONCLUSIONS: We found less inter-observer variability when contouring on CT than on MRI. Radiation Therapy Oncology Group contouring guidelines are based on anatomical landmarks readily visible on CT. These landmarks are more inter-observer dependent on MRI. Therefore, present contouring guidelines might not be applicable to MRI planning.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.014
metaresearch head score (Gemma)0.038
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.014
Threshold uncertainty score0.073

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0140.038
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.001
Bibliometrics0.0010.001
Science and technology studies0.0000.000
Scholarly communication0.0010.001
Open science0.0000.001
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.016
GPT teacher head0.366
Teacher spread0.350 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations21
Published2015
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Medical Imaging and Radiation OncologySame topicAdvanced Radiotherapy TechniquesFrench-language works237,207