MétaCan
Menu
Back to cohort
Record W2282777487 · doi:10.12968/jowc.2016.25.2.87

Photoacoustic imaging of real-time oxygen changes in chronic leg ulcers after topical application of a haemoglobin spray: a pilot study

2016· article· en· W2282777487 on OpenAlexaff
Maximilian Petri, Ingo Stoffels, Jithin Jose, Julia Leyh, A. Schulz, Joachim Dissemond, Dirk Schadendorf, Joachim Klode

Bibliographic record

VenueJournal of Wound Care · 2016
Typearticle
Languageen
FieldEngineering
TopicPhotoacoustic and Ultrasonic Imaging
Canadian institutionsFujiFilm VisualSonics (Canada)
Fundersnot available
KeywordsMedicineOxygenationPhotoacoustic imaging in biomedicineOxygen saturationOxygenSaturation (graph theory)Oxygen deliveryBiomedical engineeringAnesthesiaSurgeryOptics

Abstract

fetched live from OpenAlex

OBJECTIVE: To use a non-invasive measurement of oxygen saturation in chronic leg ulcers after the application of a topical haemoglobin spray to investigate if photoacoustic tomography is able to measure the oxygen saturation and if the stimulated oxygen increase can be demonstrated. METHOD: We measured the oxygen saturation of the ulcer tissue in five patients with chronic leg ulcers before application and 5 and 20 minutes after application of the haemoglobin spray, using photoacoustic tomography as a new method to assess oxygenation in real-time. RESULTS: The average oxygen saturation showed a significant increase from 56.4% before to 69% (p=0.042) after 5 minutes and 78.8% (p=0.043) 20 minutes after the topical haemoglobin application. CONCLUSION: The oxygenation status of chronic, hard-to-heal wounds is gaining increasing interest in modern wound therapy. Topical haemoglobin spray is a new and effective method to increase the oxygenation in the ulcer tissue, but until now the link between clinical results and the mode of action was unclear. We were able to show for the first time that the use of a topical haemoglobin spray leads to an increase in oxygen saturation in vivo using photoacoustic tomography. DECLARATION OF INTEREST: Joachim Dissemond received financial support from the company SastoMed for several scientific projects as well as for lectures and as an advisor. The haemoglobin spray was provided by SastoMed GmbH (Georgsmarienhütte, Germany).

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.003
Threshold uncertainty score0.008

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0030.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.006
GPT teacher head0.226
Teacher spread0.220 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations50
Published2016
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Wound CareSame topicPhotoacoustic and Ultrasonic ImagingFrench-language works237,207