MétaCan
Menu
Back to cohort
Record W2284538908 · doi:10.1002/mrm.26146

High‐resolution dynamic CE‐MRA of the thorax enabled by iterative TWIST reconstruction

2016· article· en· W2284538908 on OpenAlexaff
Jens Wetzl, Christoph Forman, Bernd J. Wintersperger, Luigia D’Errico, Michaela Schmidt, Boris Mailhé, Andreas Maier, Aurélien F. Stalder

Bibliographic record

VenueMagnetic Resonance in Medicine · 2016
Typearticle
Languageen
FieldMedicine
TopicAdvanced MRI Techniques and Applications
Canadian institutionsToronto General HospitalUniversity of TorontoUniversity Health Network
FundersErlangen Graduate School of Advanced Optical TechnologiesDeutsche Forschungsgemeinschaft
KeywordsIterative reconstructionImage qualityComputer scienceScannerMagnetic resonance angiographyIterative methodImage resolutionTwistNuclear medicineAlgorithmMagnetic resonance imagingComputer visionArtificial intelligenceRadiologyMathematicsMedicineImage (mathematics)

Abstract

fetched live from OpenAlex

PURPOSE: To evaluate the clinical benefit of using a new iterative reconstruction technique fully integrated on a standard clinical scanner and reconstruction system using a TWIST acquisition for high-resolution dynamic three-dimensional contrast-enhanced MR angiography (CE-MRA). METHODS: Low-dose, high-resolution TWIST datasets of 11 patients were reconstructed using both standard GRAPPA-based reconstruction for reference and iterative reconstruction, which reduces the temporal footprint of reconstructed images. Image quality of both techniques was assessed by two experienced readers, as well as quantitatively evaluated using a time-signal curve analysis. RESULTS: Image quality scores consistently and significantly improved by using iterative reconstruction compared with the standard approach. Most notably, the delineation of small to mid-size vasculature improved from a mean Likert score between "nondiagnostic" and "poor" for standard to between "good" and "excellent" for iterative reconstruction. The full width at half maximum of the contrast agent bolus computed from the time-signal curve was also reduced by iterative reconstruction, allowing for more precise bolus timing. CONCLUSION: Iterative reconstruction can substantially improve high-resolution dynamic CE-MRA image quality, most notably in small to mid-size vasculature. Dynamic CE-MRA with iterative reconstruction could become an alternative to conventional static 3D CE-MRA, thus simplifying the clinical workflow. Magn Reson Med 77:833-840, 2017. © 2016 International Society for Magnetic Resonance in Medicine.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.004
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Methods · Consensus signal: none
Teacher disagreement score0.001
Threshold uncertainty score0.007

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.004
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0010.001
Open science0.0000.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0010.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.009
GPT teacher head0.282
Teacher spread0.273 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreMethods

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations22
Published2016
Admission routes1
Has abstractyes

Explore more

Same venueMagnetic Resonance in MedicineSame topicAdvanced MRI Techniques and ApplicationsFrench-language works237,207