Augmented Reality System for Ultrasound Guidance of Transcatheter Aortic Valve Implantation

2016· article· en· W2291662546 on OpenAlexafffund
Maria Currie, A. Jonathan McLeod, John Moore, Michael Chu, Rajni V. Patel, Bob Kiaii, Terry M. Peters

Bibliographic record

VenueInnovations Technology and Techniques in Cardiothoracic and Vascular Surgery · 2016
Typearticle
Languageen
FieldMedicine
TopicCardiac Valve Diseases and Treatments
Canadian institutionsLondon Health Sciences CentreLawson Health Research InstituteWestern University
FundersCanadian Institutes of Health ResearchLondon Health Sciences Centre
KeywordsFluoroscopyAortic valveCardiac skeletonMedicineAortic rootRadiologyAortaSurgery

Abstract

fetched live from OpenAlex

OBJECTIVE: Transcatheter aortic valve implantation (TAVI) relies on fluoroscopy and nephrotoxic contrast medium for valve deployment. We propose an alternative guidance system using augmented reality (AR) and transesophageal echocardiography (TEE) to guide TAVI deployment. The goals of this study were to determine how consistently the aortic valve annulus is defined from TEE using different aortic valve landmarks and to compare AR guidance with fluoroscopic guidance of TAVI deployment in an aortic root model. METHODS: Magnetic tracking sensors were integrated into the TAVI catheter and TEE probe, allowing these tools to be displayed in an AR environment. Variability in identifying aortic valve commissures and cuspal nadirs was assessed using TEE aortic root images. To compare AR guidance of TAVI deployment with fluoroscopic guidance, a TAVI stent was deployed 10 times in the aortic root model using each of the two guidance systems. RESULTS: Commissures and nadirs were both investigated as features for defining the valve annulus in the AR guidance system. The commissures were identified more consistently than the nadirs, with intraobserver variability of 2.2 and 3.8 mm, respectively, and interobserver variability of 3.3 and 4.7 mm, respectively. The precision of TAVI deployment using fluoroscopic guidance was 3.4 mm, whereas the precision of AR guidance was 2.9 mm, and its overall accuracy was 3.4 mm. This indicates that both have similar performance. CONCLUSIONS: Aortic valve commissures can be identified more reliably than cuspal nadirs from TEE. The AR guidance system achieved similar deployment accuracy to that of fluoroscopy while eliminating the use and consequences of nephrotoxic contrast and radiation.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.127
Threshold uncertainty score0.414

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.001
Bibliometrics0.0010.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.018
GPT teacher head0.339
Teacher spread0.320 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations26
Published2016
Admission routes2
Has abstractyes

Explore more