MétaCan
Menu
Back to cohort
Record W2292362470 · doi:10.1109/jstqe.2015.2494532

Frequency-Domain Photoacoustic Phase Spectroscopy: A Fluence-Independent Approach for Quantitative Probing of Hemoglobin Oxygen Saturation

2015· article· en· W2292362470 on OpenAlexafffund
Bahman Lashkari, Sung Soo Choi, Edem Dovlo, Saheb Dhody, Andreas Mandelis

Bibliographic record

VenueIEEE Journal of Selected Topics in Quantum Electronics · 2015
Typearticle
Languageen
FieldEngineering
TopicPhotoacoustic and Ultrasonic Imaging
Canadian institutionsUniversity of Toronto
FundersNatural Sciences and Engineering Research Council of Canada
KeywordsPhotoacoustic spectroscopyHemoglobinAttenuation coefficientChromophoreFluenceMaterials scienceOxygen saturationOpticsSaturation (graph theory)Absorption (acoustics)Analytical Chemistry (journal)Photoacoustic imaging in biomedicineBiomedical engineeringBiological systemNuclear magnetic resonanceComputer scienceChemistryOxygenPhysicsMathematicsChromatographyLaserPhotochemistry

Abstract

fetched live from OpenAlex

In this paper, it is shown that the phase of the frequency-domain photoacoustic (PA) signal can be used to measure the absorption coefficient (μ <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">α</sub> ) of the chromophore. This method can be referred to as a calibration-free approach in the sense that it is not affected by the attenuation of fluence in the tissue. This helps to enhance the accuracy of quantitative PA functional imaging. However, the premise for employing the aforementioned method is that chromophore geometry should be known a priori. As a proof of applicability of the theory, the method was applied to a simplified geometry and the extension of the method to more complicated geometries is discussed. One of the key subjects of functional imaging in medicine is blood. Parameters such as total hemoglobin concentration and hemoglobin oxygen saturation are valuable for diagnostics as well as for treatment of many diseases. The developed method was employed for in vitro monitoring of blood oxygenation on heparinized sheep blood and is applicable to characterization problems in biological tissues and other turbid media.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.674
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.021
GPT teacher head0.277
Teacher spread0.255 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations15
Published2015
Admission routes2
Has abstractyes

Explore more

Same venueIEEE Journal of Selected Topics in Quantum ElectronicsSame topicPhotoacoustic and Ultrasonic ImagingFrench-language works237,207