MétaCan
Menu
Back to cohort
Record W2294578285 · doi:10.1109/tmech.2015.2482391

Physiological Organ Motion Prediction and Compensation Based on Multirate, Delayed, and Unregistered Measurements in Robot-Assisted Surgery and Therapy

2015· article· en· W2294578285 on OpenAlexafffund
Meaghan Bowthorpe, Mahdi Tavakoli

Bibliographic record

VenueIEEE/ASME Transactions on Mechatronics · 2015
Typearticle
Languageen
FieldEngineering
TopicSoft Robotics and Applications
Canadian institutionsUniversity of Alberta
FundersCanadian Network for Research and Innovation in Machining Technology, Natural Sciences and Engineering Research Council of CanadaCanada Foundation for Innovation
KeywordsRobotComputer scienceKalman filterTeleoperationRendering (computer graphics)Computer visionArtificial intelligenceSurgical robotCompensation (psychology)Simulation

Abstract

fetched live from OpenAlex

Physiological motion makes performing a surgical or therapeutic procedure more difficult for the physician. In heart surgery, the heart is stopped as it is too difficult for the surgeon to follow the heart's beating motion and perform a surgical task. In radiation therapy, respiration causes the cancerous tissue to move, rendering the therapy less effective and possibly damaging to healthy tissue. This paper focuses on controlling a robot, which is used to perform the surgery or therapy, to compensate for the physiological motion along the surgical tool's axis such that the point of interest (POI) on the organ becomes stationary relative to the robot. The difficulty in creating such a system lies in the measurement of the POI's and robot's positions via different sensors that are unregistered, have different measurement rates, and have data acquisition and processing delays. This paper presents the Kalman-filter-based estimation of the organ motion despite the large data acquisition/processing delays and low update rates inherent in some measurements used for robot control in robot-assisted surgeries and therapies. This paper also proposes control systems that compensate for the organ motion despite the delayed, multirate, and unregistered sensor data allowing the physician to perform a therapeutic or surgical procedure with a teleoperated robot on a seemingly stationary POI.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: Simulation or modeling
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.319
Threshold uncertainty score0.726

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.107
GPT teacher head0.255
Teacher spread0.148 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations17
Published2015
Admission routes2
Has abstractyes

Explore more

Same venueIEEE/ASME Transactions on MechatronicsSame topicSoft Robotics and ApplicationsFrench-language works237,207