MétaCan
Menu
Back to cohort
Record W2297087722 · doi:10.1117/12.2211109

Photoacoustic imaging using lock-in amplification and pulsed fiber lasers

2016· article· en· W2297087722 on OpenAlexafffund
Wei Shi, Parsin Haji Reza, Roger J. Zemp

Bibliographic record

VenueProceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · 2016
Typearticle
Languageen
FieldEngineering
TopicPhotoacoustic and Ultrasonic Imaging
Canadian institutionsUniversity of Alberta
FundersNatural Sciences and Engineering Research Council of CanadaAlberta InnovatesProstate Cancer CanadaMovember Foundation
KeywordsLaserMaterials scienceOpticsFiber laserTime domainTransducerOptoelectronicsPhysicsComputer science

Abstract

fetched live from OpenAlex

Photoacoustic (PA) imaging is a non-invasive, non-ionizing imaging technology with high optical contrast between blood and tissue, and with high sensitivity of hemoglobin concentration and oxygen saturation due to different optical absorption spectra resulting from different oxygenation of hemoglobin. Most PA imaging systems implement a nanosecond pulsed laser source as excitation source to induce PA signal, and rely on broadband amplifiers to record time-domain PA signals [1-6]. Some groups, however, have reported using modulated continuous-wave lasers as an excitation source for frequency-domain imaging [7-9]. Frequency-domain imaging offers the potential of lock-in amplification which has sensitivities as low as nV even in noise orders of magnitude higher than the signal. However, although modulated CW sources works for low cost and compact PA imaging, it does not satisfy thermal and stress confinement conditions required for optimal PA signal strength. Here, we investigate a PA methodology using pulsed fiber lasers as excitation laser source combined with lock-in amplification technology. For comparison, we also studied time-domain PA methodology. Phantom studies show that signal-to-noise ratio (SNR) obtained with frequency domain PA imaging is significantly more sensitive than that obtained using time-domain PA imaging when the laser pulse repetition rate (PRR) matches the bandwidth of ultrasound transducer. Therefore, high sensitive PA imaging technology using pulsed fiber laser sources with lock-in amplification may potentially greatly extend the depth of PA imaging.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.001
Threshold uncertainty score0.004

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.001
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.009
GPT teacher head0.216
Teacher spread0.206 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations2
Published2016
Admission routes2
Has abstractyes

Explore more

Same venueProceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIESame topicPhotoacoustic and Ultrasonic ImagingFrench-language works237,207