Polyisobutylene‐paclitaxel conjugates with pendant carboxylic acids and polystyrene chains: Towards multifunctional stent coatings with slow drug release
Bibliographic record
Abstract
ABSTRACT Drug‐eluting stents are used in the treatment of atherosclerosis, where the incorporation of anti‐proliferative or anti‐inflammatory drugs decreases the rate of restenosis, the recurrence of artery narrowing. However, these stents can suffer from limitations such as drug depletion and delamination of the drug‐eluting coating from the stent surface. Described here is an approach aimed at addressing these issues. Starting from a maleic anhydride adduct of polyisobutylene (PIB) prepared from butyl rubber, ring opening using paclitaxel (PTX) or a combination of PTX and polystyrene (PS) afforded covalent conjugates of PTX and PIB or PIB‐PS graft copolymers bearing pendant carboxylic acids. When coated on stainless steel, the drug release was slower than that from a control coating that ressembles a clinical formulation comprising a physical mixture of a PS‐PIB‐PS triblock copolymer (SIBS) and PTX. The PTX conjugates also exhibited enhanced adhesion to stainless steel and increased tensile strength in comparison with the starting rubber. Cytotoxicity assays indicated that the materials did not leach toxic levels of PTX into cell culture media. Nevertheless, they were capable of inhibiting the adhesion and proliferation of C2C12 cells on their surfaces. These properties are advantageous for the potential application of the materials as stent coatings. © 2016 Wiley Periodicals, Inc. J. Polym. Sci., Part A: Polym. Chem. 2016, 54, 2209–2219
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame machine prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.
Distilled classifier scores by category (both heads)
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.000 | 0.000 |
| Meta-epidemiology (narrow) | 0.001 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.001 | 0.001 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".