MétaCan
Menu
Back to cohort
Record W2300842986 · doi:10.14740/jocmr2491w

Unresolved or Contradictory Issues About Management of Patients With Patent Foramen Ovale and Previous Cryptogenic Stroke: Additional Randomized Controlled Trials Are Eagerly Awaited

2016· review· en· W2300842986 on OpenAlexvenueno aff
Renato De Vecchis, Cesare Baldi

Bibliographic record

VenueJournal of Clinical Medicine Research · 2016
Typereview
Languageen
FieldMedicine
TopicCardiovascular and Diving-Related Complications
Canadian institutionsnot available
Fundersnot available
KeywordsMedicinePatent foramen ovaleRandomized controlled trialStroke (engine)Foramen ovale (heart)Medical therapyAntithromboticInternal medicineIntensive care medicineCardiologySurgeryMigraine

Abstract

fetched live from OpenAlex

Stating a well-codified and widely accepted therapeutic conduct for patients with patent foramen ovale (PFO) and previous cryptogenic stroke is made difficult and somewhat controversial by several issues remained unresolved so far. In this short review, some aspects of the possible role played by the PFO in the pathogenesis of cryptogenic stroke are succinctly analyzed. First, some aspects of cardiovascular anatomy of the human fetus and the adult are outlined. Subsequently, the three randomized controlled trials (RCTs) that have been accomplished so far to compare the implant of a transeptal occluding device with a simple medical therapy in patients with PFO and history of cryptogenic stroke are briefly examined. These RCTs, when assessed using the "intention to treat" method, do not show a greater protective effect of therapy with transeptal device as regards the recurrences of stroke. Afterwards, there is a brief presentation of the findings of several meta-analyses that have been derived from the three above mentioned RCTs, whose results are strikingly discordant with each other. In fact, some of them come to the conclusion that the transcatheter closure of PFO does not offer significant advantages compared to antithrombotic therapy for the secondary prevention of cryptogenic stroke, while others based on subgroup analyses argue that the transcatheter closure of PFO with Amplatzer device, differently from the one performed using the STARFlex device, would be associated with significantly lower incidence of cerebrovascular events compared with medical therapy alone. Finally, the authors argue the need to adhere to the current scientific guidelines. They substantially deny an alleged superior efficacy of transcatheter PFO occlusion compared to medical therapy with antithrombotic agents (anticoagulants or antiplatelet agents), except for selected cases of patients with documented PFO and concomitant clinical-instrumental picture of deep venous thrombosis.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.048
metaresearch head score (Gemma)0.033
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMetaresearch, Meta-epidemiology (broad), Insufficient payload (model declined to judge)
Consensus categoriesMetaresearch
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Randomized trial · Consensus signal: none
GenreCandidate signal: Review · Consensus signal: Review
Teacher disagreement score0.525
Threshold uncertainty score0.998

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0480.033
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0230.005
Bibliometrics0.0010.001
Science and technology studies0.0000.001
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0010.002
Insufficient payload (model declined to judge)0.0020.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.349
GPT teacher head0.526
Teacher spread0.177 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; both teacher heads agree on what is shown here.

Study designRandomized trial
Domainnot available
GenreReview

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations4
Published2016
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Clinical Medicine ResearchSame topicCardiovascular and Diving-Related ComplicationsFrench-language works237,207