MétaCan
Menu
Back to cohort
Record W2301120389 · doi:10.25916/sut.26269843

Experimental study of zeotropic refrigerant mixture HFC-407C as a replacement for HCFC-22 in refrigeration and air-conditioning systems

2006· article· en· W2301120389 on OpenAlexaboutno aff
Changiz M. Mirza-Tolouee

Bibliographic record

VenueSwinburne Research Bank (Swinburne University of Technology) · 2006
Typearticle
Languageen
FieldEngineering
TopicRefrigeration and Air Conditioning Technologies
Canadian institutionsnot available
Fundersnot available
KeywordsZeotropic mixtureRefrigerantAir conditioningRefrigerationThermodynamicsEnvironmental scienceGas compressorPhysics

Abstract

fetched live from OpenAlex

HCFC-22 is the world's most widely used refrigerant. It serves in both residential and commercial applications, from small window units to large water chillers, and everything in between. Its particular combination of efficiency, capacity and pressure has made it a popular choice for equipment designers. Nevertheless, it does have some ODP, so international law set forth in the Montreal Protocol and its Copenhagen and Vienna amendments have put HCFC-22 on a phase out schedule. In developed countries, production of HCFC-22 will end no later than the year 2030. Zeotropic blend HFC-407C has been established as a drop-in alternative for HCFC-22 in the industry due to their zero Ozone Depletion Potential (ODP) and similarities in thermodynamic properties and performance. However, when a system is charged with a zeotropic mixture, it raises concerns about temperature glide at two-phase state, differential oil solubility and internal composition shift. Not enough research has been done to cover all aspects of alternative refrigerants applications in the systems. This research intended to explore behavior of this alternative refrigerants compare to HCFC-22 and challenges facing the industry in design, operation service and maintenance of these equipments. The purpose of this research is to investigate behavior of R407C refrigerant in chiller systems. This includes performance and efficiency variations when it replaces R22 in an existing system as well as challenges involved maintaining the system charged with R407C. It is a common practice in the industry these days to evacuate and completely recharge when part of the new refrigerant blend was leaked from the system. This has proved to be extremely costly exercise with grave environmental ramifications. This research is intended to address challenges faced in the real world and practical terms. Theoretical and experimental approaches used as a methodology in this work. The system mathematically modeled to predict detailed system performance and effect of the leak at various conditions. To make this feasible and accurate enough, two separate approaches made, first system performance for pure R22 and R407C, and second system subjected to range of leak fractions. The earlier model was relatively straight forward when compared to the latter. Modeling a system charged with R407C ternary mixture and subjected to range of leaks posed enormous challenges. A sophisticated experimental test apparatus was also designed and built. Comprehensive and detailed tests at various conditions were conducted with special attention on instrumental accuracy and correct methodology. The first part has been successfully modeled and predicted all the factors and performance with excellent accuracy when compared to the test results. In these approaches pure refrigerants R22 and R407C were used and simulated the system behavior at range of conditions. However, the second part was the most challenging ever. Comprehensive leak process simulations produced trends of R32/R125/R134a composition change as function of rate of leak. Starting from this point, equations have been created to represent the composition change as function of percentage of the leak. The system thermodynamic cycle was also modeled to calculate capacity, power input and COP at the range of the conditions. Despite many affecting parameters and complexity of the model, the mathematical model successfully predicted the test outcome with a very reasonable accuracy, averaging around 3% with some times reaching to 5 to 6%. On the experimental stage the system charged with the new HFC-407C was deliberately subjected to refrigerant leak at various leak stages. The aim was to objectively determine to what extend the gas leak can be still acceptable without going through the expensive complete gas charge. The effect of leak was tested and verified at 10% steps, from 10% up to 50% mass fraction for the total charge. It has been observed that at the leaks beyond 30%, the adverse effect on the capacity becomes more significant, from 8 to about 15% decrease. While the power input decreased at slower pace, from 3% up to about 8% depending on the test conditions. This translated to COP decrease ranging from 4 to about 7%. This capacity loss and efficiency decrease are significant figures which suggests that the system, here chiller, can not be allowed to degrade the performance to that extend and still continue operating.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.189
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0020.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.015
GPT teacher head0.268
Teacher spread0.253 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations1
Published2006
Admission routes1
Has abstractyes

Explore more

Same venueSwinburne Research Bank (Swinburne University of Technology)Same topicRefrigeration and Air Conditioning TechnologiesFrench-language works237,207