MétaCan
Menu
Back to cohort
Record W2306043895 · doi:10.1080/17583004.2015.1039251

Life cycle assessment of a hypothetical Canadian pre-combustion carbon dioxide capture process system

2014· article· en· W2306043895 on OpenAlexaffabout
Lakkana Piewkhaow, Christine W. Chan, Anastassia Manuilova, Malcolm Wilson, Paitoon Tontiwachwuthikul

Bibliographic record

VenueCarbon Management · 2014
Typearticle
Languageen
FieldEngineering
TopicCarbon Dioxide Capture Technologies
Canadian institutionsUniversity of Regina
FundersU.S. Department of Energy
KeywordsIntegrated gasification combined cycleEnvironmental scienceLife-cycle assessmentWaste managementCoalPulverized coal-fired boilerCombustionPollutionGreenhouse gasClean coal technologyElectricity generationEnvironmental engineeringEngineeringChemistryProduction (economics)

Abstract

fetched live from OpenAlex

The methodology of life cycle assessment was applied for evaluating the environmental performance of a Saskatchewan lignite integrated gasification combined cycle (IGCC)-based electricity generation plant with and without the pre-combustion CO2 capture process. A comparison between the IGCC systems (with and without CO2 capture) and the competing lignite pulverized coal electricity generating station was conducted to reveal which technology offers more positive environmental effects. The results showed significant reduction of GHG emissions where both post- and pre-combustion CO2 capture processes are applied. With the application of the CO2 removal technology, GHG emissions were reduced by 27–86%. The performances of the IGCC systems were superior to those of the pulverized coal systems. However, in terms of other environmental impacts, multiple environmental trade-offs are involved depending on the capture technology. For the post-combustion CO2 capture process system, it was observed that the environmental impact was shifted from the air compartment to the soil and water compartments. The IGCC systems showed the same tendency of shifting from air pollution to soil and water pollution, but the amount of pollution is less significant. This is likely because the IGCC system operates at higher efficiencies; hence, it requires less fuel and produces fewer emissions.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: Simulation or modeling
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.081
Threshold uncertainty score0.206

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0010.001
Science and technology studies0.0020.001
Scholarly communication0.0010.001
Open science0.0010.000
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0040.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.005
GPT teacher head0.204
Teacher spread0.199 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations7
Published2014
Admission routes2
Has abstractyes

Explore more

Same venueCarbon ManagementSame topicCarbon Dioxide Capture TechnologiesFrench-language works237,207