High performance liquid chromatographic determination of cyclooxygenase II inhibitor rofecoxib in rat and human plasma.
Bibliographic record
Abstract
Rofecoxib is a relatively new non-steroidal anti-inflammatory drug with high selectivity in cyclooxygenase 2 inhibitory activity. There is only one assay reported for determination of the drug in biological samples. The assay requires a post-column UV reactor for photocyclization before detection with fluorescence detector. In addition, the internal standard (IS) used in the assay in not commercially available. We developed a new assay for determination of rofecoxib. Rat blank plasma (200 microL) or human blank plasma (500 microL) was spiked with rofecoxib to make final concentrations of 10 to 3000 ng/mL, and 100 microl of a 2 microg/mL of ketoprofen as IS, 100 microl of a pH 4.5 acetate buffer, and 6 mL of ethyl acetate were added. The resultant was vortex-mixed for 90 seconds and centrifuged at 2500 g for 3 min. The organic layer was separated and evaporated to dryness under vacuum. The residues were reconstituted in 170 microL of mobile phase and 150 microL was injected into an HPLC consisting of an autoinjector, an isocratic pump, a 10 cm 4.6 i.d. C(18) analytical column packed with 5 microm reversed phase particles, a variable UV spectrophotometer detector set at 272 nm, and an integrator. The mobile phase consisted of water (77%), acetonitrile (23%), acetic acid (0.1%), and triethylamine (0.03%) and was pumped at 1 mL/min at ambient temperature. The drug and IS were eluted at 13 and 24 min, respectively. The peak drug/IS area ratio versus drug concentrations relationship was linear (r>0.99). The extraction efficiency was >87%. The minimum quantifiable concentration was set at 10 ng/mL (correlation coefficient of <10%). This convenient, sensitive, and simple method is suitable to pharmacokinetic studies of rofecoxib in rats and humans.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.000 | 0.000 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.000 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one teacher head, not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".