MétaCan
Menu
Back to cohort
Record W2310442715

Bone marrow dosimetry using blood-based models for radiolabeled antibody therapy: a multiinstitutional comparison.

2004· article· en· W2310442715 on OpenAlexaff
Barry W. Wessels, Wesley E. Bolch, Lionel G. Bouchet, Hazel B. Breitz, Gerald L. DeNardo, Ruby F. Meredith, Michael G. Stabin, George Sgouros

Bibliographic record

VenuePubMed · 2004
Typearticle
Languageen
FieldMedicine
TopicRadiopharmaceutical Chemistry and Applications
Canadian institutionsNexen (Canada)
Fundersnot available
KeywordsDosimetryMedicineBone marrowRadioimmunotherapyRadionuclide therapyNuclear medicineClinical trialMedical physicsInternal medicineAntibodyImmunology
DOInot available

Abstract

fetched live from OpenAlex

UNLABELLED: Standardization of marrow dosimetry is of considerable importance when estimating dose-response for a multicentered clinical trial involving radionuclide therapy. However, it is only within the past five years that the intercomparison of marrow dosimetry results among separate clinical trials that use the same agent has become scientifically feasible. In this work, we have analyzed reported marrow dosimetry results from radioimmunotherapy trials and recalculated marrow absorbed doses at a central facility using a standard blood model with patient-specific source data. The basic approach used in the American Association of Physicists in Medicine (AAPM)/Sgouros marrow dosimetry methodology was common to calculation performed at all participating institutions, including the central facility. Differences in dose estimates associated with starting assumptions and the exact implementation of the AAPM/Sgouros calculation methodology used by the source institutions and the central facility were quantified and compared. METHODS: Data from 22 patients enrolled in radiolabeled antibody clinical trials were randomly selected from 7 participating institutions for the assessment of marrow dose. The analysis was restricted to those patients who were treated with 131I- or 186Re-labeled antibody and had no marrow involvement. Calculation of bone marrow dose at each participating institution was unique to the trial or institution, but all used some form of the AAPM/Sgouros blood model approach. The central facility adopted a marrow dosimetry model based on the AAPM/Sgouros model for radiolabeled antibodies using the standard MIRD approach to the remainder-of-body contribution. A standardized approach to account for variations in patient mass was used for the remainder-of-body component. To simplify clinical implementation, regional marrow uptake and time-dependent changes in the marrow-to-blood concentration ratio were not included. Methods of formatting the collection of standard datasets useful in defining dose-response parameters are also presented. RESULTS: Bone marrow doses were calculated according to the method described for each of the 22 patients based on the patient-specific data supplied by the participating institutions. These values were then individually compared with the marrow doses originally reported by each institution. Comparison of the two calculation methods was expressed as a ratio of the marrow doses for each patient. The mean ratio for the dose estimates at the participating institution calculation compared with the central laboratory value was 0.920 +/- 0.259 (mean +/- SD), with a range from 0.708 to 1.202. CONCLUSION: The independent use of the AAPM/Sgouros method blood model approach to marrow dosimetry has brought these dose estimates to within 30% of the results obtained centrally compared with substantially higher uncertainties reported previously. Variations in calculation methodology or initial assumptions adopted by individual institutions may still contribute significant uncertainty to dose estimates, even when the same data are used as a starting point for the calculation comparison shown here. A clinically relevant, standard method for marrow dosimetry for radiolabeled antibodies is proposed as a benchmark for intercomparison purposes. A parameter sensitivity analysis and a summary discussion of the use of this model for potentially improving dose-response data correlation are also presented.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.110
Threshold uncertainty score0.605

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.102
GPT teacher head0.354
Teacher spread0.253 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations66
Published2004
Admission routes1
Has abstractyes

Explore more

Same venuePubMedSame topicRadiopharmaceutical Chemistry and ApplicationsFrench-language works237,207