Investigation Of Photon Shielding Property Changes in Curing High Density Concrete
Why this work is in the frame
A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.
Bibliographic record
Abstract
High density concrete is usually used for radiation shielding around radiotherapy treatment rooms. Because the concrete is specified differently at the design, construction, and verification stages, the relationship between the intended performance and the actual performance of the shielding material might not be entirely clear. In this study, cylindrical samples of high density shielding concrete were taken as each section of a new radiotherapy bunker was poured. The shielding performance of each sample [measured by beam attenuation and tenth-value layers (TVL)] was evaluated for 15 MV and 6 MV x-ray beams and for the 1.25 MeV monoenergetic gamma beam from a Co source. Transmission curves to 3 TVL were mapped for a representative sample. The samples were also imaged and analyzed using Co Cone Beam Computed Tomography (CoCBCT). Results indicate no significant change in the TVL of high density concrete samples as they cure. The minor fluctuations in shielding properties observed are explained by the heterogeneous structure of the samples as indicated in the CoCBCT images.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.000 | 0.000 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.000 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it