Radiation Minimisation and Outcome Maximisation in Cardiac Computed Tomograpy
Bibliographic record
Abstract
Recent reports have raised general awareness that cardiac computed tomography (CT) has the potential for relatively high effective radiation doses. While the actual amount of risk this poses to the patient is controversial, the increasing concern has led to a great deal of research on new CT techniques capable of imaging the heart at substantially lower radiation doses than was available only a few years ago. Methods of dose reduction include optimised selection of user-defined parameters, such as tube current and voltage, as well as use of new technologies, such as prospective triggering and iterative reconstruction. These techniques have each been shown to lead to substantial reduction in radiation dose without loss of diagnostic accuracy. This article will review the most frequently used and widely available methods for radiation dose reduction in cardiac CT and give practical advice on their use and limitations.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.001 | 0.000 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.000 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one teacher head, not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".