MétaCan
Menu
Back to cohort
Record W2317451226 · doi:10.1021/ac2034503

State-of-the Art Comparability of Corrected Emission Spectra.1. Spectral Correction with Physical Transfer Standards and Spectral Fluorescence Standards by Expert Laboratories

2012· article· en· W2317451226 on OpenAlexaff
Ute Resch‐Genger, Wolfram Bremser, Dietmar Pfeifer, Monika Spieles, Angelika Hoffmann, Paul C. DeRose, Joanne C. Zwinkels, François Gauthier, Bernd Ebert, R. Taubert, C. Monte, Jan Voigt, J. Hollandt, Rainer Macdonald

Bibliographic record

VenueAnalytical Chemistry · 2012
Typearticle
Languageen
FieldBiochemistry, Genetics and Molecular Biology
TopicAdvanced Fluorescence Microscopy Techniques
Canadian institutionsNational Research Council Canada
Fundersnot available
KeywordsComparabilityCalibrationNISTEmission spectrumChemistrySpectral lineAnalytical Chemistry (journal)MetrologyFluorescenceMeasurement uncertaintyCertified reference materialsRemote sensingOpticsStatisticsPhysicsComputer scienceDetection limitMathematicsEnvironmental chemistry

Abstract

fetched live from OpenAlex

The development of fluorescence applications in the life and material sciences has proceeded largely without sufficient concern for the measurement uncertainties related to the characterization of fluorescence instruments. In this first part of a two-part series on the state-of-the-art comparability of corrected emission spectra, four National Metrology Institutes active in high-precision steady-state fluorometry performed a first comparison of fluorescence measurement capabilities by evaluating physical transfer standard (PTS)-based and reference material (RM)-based calibration methods. To identify achievable comparability and sources of error in instrument calibration, the emission spectra of three test dyes in the wavelength region from 300 to 770 nm were corrected and compared using both calibration methods. The results, obtained for typical spectrofluorometric (0°/90° transmitting) and colorimetric (45°/0° front-face) measurement geometries, demonstrated a comparability of corrected emission spectra within a relative standard uncertainty of 4.2% for PTS- and 2.4% for RM-based spectral correction when measurements and calibrations were performed under identical conditions. Moreover, the emission spectra of RMs F001 to F005, certified by BAM, Federal Institute for Materials Research and Testing, were confirmed. These RMs were subsequently used for the assessment of the comparability of RM-based corrected emission spectra of field laboratories using common commercial spectrofluorometers and routine measurement conditions in part 2 of this series (subsequent paper in this issue).

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.049
metaresearch head score (Gemma)0.074
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.049
Threshold uncertainty score0.259

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0490.074
Meta-epidemiology (narrow)0.0020.001
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0050.003
Science and technology studies0.0020.003
Scholarly communication0.0060.005
Open science0.0070.004
Research integrity0.0040.003
Insufficient payload (model declined to judge)0.0040.003

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.004
GPT teacher head0.273
Teacher spread0.269 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations31
Published2012
Admission routes1
Has abstractyes

Explore more

Same venueAnalytical ChemistrySame topicAdvanced Fluorescence Microscopy TechniquesFrench-language works237,207