MétaCan
Menu
← Back to cohort
Record W2318240467 · doi:10.2196/rehab.4511

Novel Use of a Smartphone to Measure Standing Balance

2016· article· en· W2318240467 on OpenAlexaffvenue
Nirtal Shah, Rosanne Aleong, Ivan So

Bibliographic record

VenueJMIR Rehabilitation and Assistive Technologies · 2016
Typearticle
Languageen
FieldHealth Professions
TopicBalance, Gait, and Falls Prevention
Canadian institutionsBaycrest HospitalUniversity of Toronto
Fundersnot available
KeywordsAccelerometerBalance (ability)AccelerationRepeated measures designPhysical medicine and rehabilitationSittingForce platformComputer sciencePhysical therapySimulationMathematicsMedicineStatistics

Abstract

fetched live from OpenAlex

BACKGROUND: Balance assessment and training is utilized by clinicians and their patients to measure and improve balance. There is, however, little consistency in terms of how clinicians, researchers, and patients measure standing balance. Utilizing the inherent sensors in every smartphone, a mobile application was developed to provide a method of objectively measuring standing balance. OBJECTIVE: We aimed to determine if a mobile phone application, which utilizes the phone's accelerometer, can quantify standing balance. METHODS: Three smartphones were positioned simultaneously above the participants' malleolus and patella and at the level of the umbilicus. Once secured, the myAnkle application was initiated to measure acceleration. Forty-eight participants completed 8 different balance exercises separately for the right and left legs. Accelerometer readings were obtained from each mobile phone and mean acceleration was calculated for each exercise at each ankle and knee and the torso. RESULTS: Mean acceleration vector magnitude was reciprocally transformed to address skewness in the data distribution. Repeated measures ANOVAs were completed using the transformed data. A significant 2-way interaction was revealed between exercise condition and the body position of the phone (P<.001). Post-hoc tests indicated higher acceleration vector magnitude for exercises of greater difficulty. ANOVAs at each body position were conducted to examine the effect of exercise. The results revealed the knee as the location most sensitive for the detection of differences in acceleration between exercises. The accelerometer ranking of exercise difficulty showed high agreement with expert clinical rater rankings (kappa statistic>0.9). CONCLUSIONS: The myAnkle application revealed significantly greater acceleration magnitude for exercises of greater difficulty. Positioning of the mobile phone at the knee proved to be the most sensitive to changes in accelerometer values due to exercise difficulty. Application validity was shown through comparison with clinical raters. As such, the myAnkle app has utility as a measurement tool for standing balance.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.003
Threshold uncertainty score0.010

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.001
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.000
Science and technology studies0.0000.000
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0030.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.049
GPT teacher head0.359
Teacher spread0.310 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations19
Published2016
Admission routes2
Has abstractyes

Explore more

Same venueJMIR Rehabilitation and Assistive Technologies→Same topicBalance, Gait, and Falls Prevention→French-language works237,207→